High frequency heart rate variability is associated with sensitivity to affective touch
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
Date
2024-09-01
Major/Subject
Mcode
Degree programme
Language
en
Pages
7
Series
Physiology and Behavior, Volume 283, pp. 1-7
Abstract
C-tactile afferents (CTs) are a class of unmyelinated, mechanosensitive nerve fibre that respond optimally to skin temperature, slow moving touch typical of a caress. They are hypothesised to signal the rewarding value of affiliative tactile interactions. While CT firing frequency is positively correlated with subjective ratings of touch pleasantness, trait differences in sensitivity to the specific hedonic value of CT targeted touch have been reported. Inter-individual differences in vagally mediated, high frequency heart rate variability (HF-HRV) have been linked to variation in visual social cognition. Thus, the aim of the present study was to examine the relationship between resting state HF-HRV and sensitivity to socially relevant CT targeted touch. 58 healthy participants first had a 5-minute electrocardiogram. They then rated the pleasantness of 5 randomly presented velocities of robotically delivered touch. Three velocities fell within (1, 3, 10 cm/s) and two outside (0.3, 30 cm/s) the CT optimal range. Each velocity was delivered twice. On a group level, affective touch ratings were described by a negative quadratic function, with CT optimal velocities rated as more pleasant than slower and faster speeds. Simple regression analysis confirmed participants’ HF-HRV was significantly predicted by the quadratic curve fit of their touch ratings, with higher HF-HRV associated with a better quadratic fit. These findings indicate that, in line with previous observations that higher HF-HRV is associated with enhanced sensitivity to visual social cues, trait differences in autonomic control could account for previously reported individual differences in CT sensitivity.Description
Publisher Copyright: © 2024 The Author(s)
Keywords
Affective touch, Heart rate variability, C-tactile afferent, Social, Touch
Other note
Citation
Pawling, R, McGlone, F & Walker, S C 2024, ' High frequency heart rate variability is associated with sensitivity to affective touch ', Physiology and Behavior, vol. 283, 114600, pp. 1-7 . https://doi.org/10.1016/j.physbeh.2024.114600