In contrast to current efforts to quantify the radiation pressure of light using nano-micromechanical resonators in cryogenic conditions, we proposed and experimentally demonstrated the radiation pressure measurement in ambient conditions by utilizing a macroscopic mechanical longitudinal oscillator with an effective mass of the order of 20 g. The light pressure on a mirror attached to the oscillator was recorded in a Michelson interferometer and results showed, within the experimental accuracy of 3.9%, a good agreement with the harmonic oscillator model without free parameters.Description
Keywords
Other note
Citation
Partanen, M, Lee, H & Oh, K 2020, 'Radiation pressure measurement using a macroscopic oscillator in an ambient environment', Scientific Reports, vol. 10, no. 1, 20419. https://doi.org/10.1038/s41598-020-77295-5