Parameter estimation of an LCL filter for control of grid converters

Loading...
Thumbnail Image

Access rights

© 2015 Institute of Electrical & Electronics Engineers (IEEE). Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work.
Post print

URL

Journal Title

Journal ISSN

Volume Title

School of Electrical Engineering | A4 Artikkeli konferenssijulkaisussa

Date

Major/Subject

Mcode

Degree programme

Language

en

Pages

8

Series

Abstract

Model-based control techniques are frequently used with grid-connected converters. This paper proposes a method for identifying model parameters of an LCL filter connected to a grid converter for control purposes. In identification, a discrete-time autoregressive moving average with exogenous input (ARMAX) model structure is used and closed-loop current control is considered. The resulting discrete-time model parameters are translated into the continuous-time physical parameters (inductance and capacitance values of the filter) by comparing the estimated discrete-time model with the analytical discrete-time model. Simulation and experimental results show that the proposed method yields good parameter estimates that are suitable for control tuning.

Description

Other note

Citation

Koppinen, Jussi & Kukkola, Jarno & Hinkkanen, Marko. 2015. Parameter estimation of an LCL filter for control of grid converters. 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia). 8. ISBN 978-89-5708-254-6 (electronic). DOI: 10.1109/icpe.2015.7167942.