Novel dissolved oxygen distribution model of a full-scale aeration tank for a municipal wastewater treatment plant in a cold climate region
No Thumbnail Available
Access rights
openAccess
CC BY
CC BY
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
Authors
Date
2024-11-01
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
16
Series
Journal of Water and Climate Change, Volume 15, issue 11, pp. 5698-5713
Abstract
Aeration is the most energy-intensive process in wastewater treatment plants (WWTP). Seasonal variation in hydraulic flow and load has a significant effect on WWTP’s aeration energy efficiency. High flow and temperature variations are common in cold climate regions, and with climate change increasing, extreme weather events will accentuate these situations. The prediction of oxygen mass transfer is crucial for minimizing the energy consumption of the aeration tank. This study presents a computational fluid dynamics model for a turbulent flow regime, simulating the hydraulics and dissolved oxygen (DO) concentration distribution of two phases, water and air bubbles, in a full-scale, as-built activated sludge tank. Model validation error was less than 15%. Different seasonal flows and temperatures were investigated by fixing liquid side oxygen mass transfer coefficient (kL) to 0.7 × 10–5 m/s and initial bubble diameter (dB) to 0.0025 m in the gas phase. The results show that variating hydraulic flow causes noticeable differences in DO distribution and higher flow could be more effective levelling in DO gradients. More even DO distribution could result in using up to a 10% lower DO setpoint value, using 3% less air for the same treatment result, thus lowering aeration energy cost.Description
Publisher Copyright: © 2024 The Authors.
Keywords
aeration, CFD, climate change, dissolved oxygen, wastewater, WWTP
Other note
Citation
Ukkonen, P, Mulas, M & Mikola, A 2024, ' Novel dissolved oxygen distribution model of a full-scale aeration tank for a municipal wastewater treatment plant in a cold climate region ', Journal of Water and Climate Change, vol. 15, no. 11, pp. 5698-5713 . https://doi.org/10.2166/wcc.2024.667