Current state of digital signal processing in myoelectric interfaces and related applications
| dc.contributor | Aalto-yliopisto | fi |
| dc.contributor | Aalto University | en |
| dc.contributor.author | Hakonen, Maria | |
| dc.contributor.author | Piitulainen, Harri | |
| dc.contributor.author | Visala, Arto | |
| dc.contributor.department | Department of Automation and Systems Technology | en |
| dc.contributor.department | Automaatio- ja systeemitekniikan laitos | fi |
| dc.contributor.lab | Autonomous systems | en |
| dc.contributor.lab | Autonomiset järjestelmät | fi |
| dc.contributor.school | Sähkötekniikan korkeakoulu | fi |
| dc.contributor.school | School of Electrical Engineering | en |
| dc.date.accessioned | 2015-03-11T10:00:21Z | |
| dc.date.available | 2015-03-11T10:00:21Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | This review discusses the critical issues and recommended practices from the perspective of myoelectric interfaces. The major benefits and challenges of myoelectric interfaces are evaluated. The article aims to fill gaps left by previous reviews and identify avenues for future research. Recommendations are given, for example, for electrode placement, sampling rate, segmentation, and classifiers. Four groups of applications where myoelectric interfaces have been adopted are identified: assistive technology, rehabilitation technology, input devices, and silent speech interfaces. The state-of-the-art applications in each of these groups are presented. | en |
| dc.description.version | Peer reviewed | en |
| dc.format.extent | 334-359 | |
| dc.format.mimetype | application/pdf | en |
| dc.identifier.citation | Hakonen, Maria & Piitulainen, Harri & Visala, Arto. 2015. Current state of digital signal processing in myoelectric interfaces and related applications. Biomedical Signal Processing and Control. P. 334-359. 1746-8094 (printed). DOI: 10.1016/j.bspc.2015.02.009 | en |
| dc.identifier.doi | 10.1016/j.bspc.2015.02.009 | |
| dc.identifier.issn | 1746-8094 (printed) | |
| dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/15360 | |
| dc.identifier.urn | URN:NBN:fi:aalto-201503112032 | |
| dc.language.iso | en | en |
| dc.publisher | Elsevier BV | en |
| dc.relation.ispartofseries | Biomedical Signal Processing and Control | en |
| dc.relation.ispartofseries | Volume 18 | |
| dc.rights | © 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license http://creativecommons.org/licenses/by-nc-nd/4.0/ | en |
| dc.rights.holder | Authors | |
| dc.subject.keyword | Surface electromyography | en |
| dc.subject.keyword | Myoelectric interface | en |
| dc.subject.keyword | Classification | en |
| dc.subject.keyword | Feature extraction | en |
| dc.subject.keyword | Pattern recognition | en |
| dc.subject.other | Biotechnology | en |
| dc.title | Current state of digital signal processing in myoelectric interfaces and related applications | en |
| dc.type | A2 Katsausartikkeli tieteellisessä aikakauslehdessä | fi |
| dc.type.dcmitype | text | en |
| dc.type.version | Final published version | en |
Files
Original bundle
1 - 1 of 1