Enhancing thermal comfort of older adults during extreme weather : Combined personal comfort system and ventilated vest

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorYounes, Jaafar
dc.contributor.authorChen, Minzhou
dc.contributor.authorGhali, Kamel
dc.contributor.authorKosonen, Risto
dc.contributor.authorMelikov, Arsen Krikor
dc.contributor.authorKilpeläinen, Simo
dc.contributor.authorGhaddar, Nesreen
dc.contributor.departmentDepartment of Energy and Mechanical Engineeringen
dc.contributor.groupauthorEnergy Conversion and Systemsen
dc.contributor.organizationAmerican University of Beirut
dc.contributor.organizationTechnical University of Denmark
dc.date.accessioned2025-04-02T08:39:18Z
dc.date.available2025-04-02T08:39:18Z
dc.date.embargoinfo:eu-repo/date/embargoEnd/2026-06-26
dc.date.issued2024-09-01
dc.descriptionPublisher Copyright: © 2024 Elsevier B.V.
dc.description.abstractThis study proposes using a personal comfort system (PCS) with a ventilated vest to improve the thermal comfort of older people in hot conditions with low energy requirements. A chair-based PCS that establishes a cool microclimate around body parts influential for thermal comfort is used with a ventilated vest that draws cool air from the established microclimate. The vest acts as an additional heat removal measure to provide adequate elderly thermal sensation (TS) with the chair PCS. The research methodology incorporates a ventilated vest model integrated with an elderly bioheat and TS models, as well as computational fluid dynamics for predicting the flow and thermal fields of microclimate and space. Models are validated by i) conducting experiments on a chair-based PCS with a vest on thermal manikin in a climatic chamber and ii) comparing predictions with published data on elderly TS. The validated models are used to evaluate the effect of combining the vest and the chair PCS on improving elderly TS. The combined system reduced the elderly TS from 0.8 to 0.5 (between neutral and slightly warm) at 33 °C microclimate with a chair PCS supply flow rate of 21 l/s and a vest suction fan flow rate of 11 l/s. In contrast, achieving a TS of 0.5 using the chair PCS alone necessitate a supply flow rate of 34 l/s, which results in 19 % higher energy consumption compared to the combined mode. Using the vest with the chair PCS is a viable solution for elderly individuals in hot conditions.en
dc.description.versionPeer revieweden
dc.format.extent27
dc.identifier.citationYounes, J, Chen, M, Ghali, K, Kosonen, R, Melikov, A K, Kilpeläinen, S & Ghaddar, N 2024, 'Enhancing thermal comfort of older adults during extreme weather : Combined personal comfort system and ventilated vest', Energy and Buildings, vol. 318, 114437. https://doi.org/10.1016/j.enbuild.2024.114437en
dc.identifier.doi10.1016/j.enbuild.2024.114437
dc.identifier.issn0378-7788
dc.identifier.issn1872-6178
dc.identifier.otherPURE UUID: 14fa1c32-607a-451c-98b9-0d75009e5ef7
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/14fa1c32-607a-451c-98b9-0d75009e5ef7
dc.identifier.otherPURE LINK: http://www.scopus.com/inward/record.url?scp=85196824600&partnerID=8YFLogxK
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/134827
dc.identifier.urnURN:NBN:fi:aalto-202504023065
dc.language.isoenen
dc.publisherElsevier
dc.relation.ispartofseriesEnergy and Buildingsen
dc.relation.ispartofseriesVolume 318en
dc.rightsembargoedAccessen
dc.subject.keywordChair microclimate system
dc.subject.keywordElderly thermal comfort
dc.subject.keywordElderly thermal sensation
dc.subject.keywordPersonal thermal management
dc.subject.keywordPersonalized comfort system
dc.subject.keywordVentilated vest
dc.titleEnhancing thermal comfort of older adults during extreme weather : Combined personal comfort system and ventilated vesten
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi

Files