Accuracy and robustness of an air-ultrasound method for non-contact heart rate and heart rate variability measurements

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorCailly, William
dc.contributor.authorGonzalez-Diaz, Raimundo
dc.contributor.authorNieminen, Heikki J.
dc.contributor.departmentDepartment of Neuroscience and Biomedical Engineeringen
dc.contributor.departmentDepartment of Information and Communications Engineeringen
dc.date.accessioned2025-10-29T07:45:54Z
dc.date.available2025-10-29T07:45:54Z
dc.date.issued2025-10-01
dc.descriptionPublisher Copyright: © 2025 Author(s).
dc.description.abstractHeart rate (HR) and heart rate variability (HRV) are critical indicators of cardiovascular health. Non-invasive techniques are essential for monitoring vital signs and indirectly measuring brain activity. This study evaluates an air-ultrasound technique for non-contact measurement of HR and HRV. We designed a system to capture skin motions related to cardiac activity, with displacements in the micrometer range. The study aimed to improve the accuracy of cardiac parameter measurement over previous methods by including respiratory tracking. The air-ultrasound method was tested in four young adult males, showing mean absolute errors in interbeat intervals compared to electrocardiogram R-R intervals, ranging from 1.5 to 11 ms, affected by individual variability and conditions. Incorporating respiratory phase information reduced errors by about 30%. Comparable or superior accuracy to contact methods like pulse oximetry, ballistocardiography, and seismocardiography was achieved with a 0.5-meter stand-off. Despite a limited, homogeneous sample in age, sex, and body mass index, the findings show significant variability in skin motion waveforms, necessitating adaptive strategies. The results indicate that this air-ultrasound technique is promising for neuroscientific, behavioral, and clinical applications, where non-contact cardiac monitoring is advantageous.en
dc.description.versionPeer revieweden
dc.format.extent16
dc.format.mimetypeapplication/pdf
dc.identifier.citationCailly, W, Gonzalez-Diaz, R & Nieminen, H J 2025, 'Accuracy and robustness of an air-ultrasound method for non-contact heart rate and heart rate variability measurements', Journal of the Acoustical Society of America, vol. 158, no. 4, pp. 2979-2994. https://doi.org/10.1121/10.0039555en
dc.identifier.doi10.1121/10.0039555
dc.identifier.issn0001-4966
dc.identifier.otherPURE UUID: e731255d-1044-4f41-9f61-a6ae717013f5
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/e731255d-1044-4f41-9f61-a6ae717013f5
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/199250699/Accuracy_and_robustness_of_an_air-ultrasound_method_for_non-contact_heart_rate_and_heart_rate_variability_measurements.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/140463
dc.identifier.urnURN:NBN:fi:aalto-202510298626
dc.language.isoenen
dc.publisherAcoustical Society of America
dc.relation.ispartofseriesJournal of the Acoustical Society of Americaen
dc.relation.ispartofseriesVolume 158, issue 4, pp. 2979-2994en
dc.rightsopenAccessen
dc.rightsCC BY
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleAccuracy and robustness of an air-ultrasound method for non-contact heart rate and heart rate variability measurementsen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Accuracy_and_robustness_of_an_air-ultrasound_method_for_non-contact_heart_rate_and_heart_rate_variability_measurements.pdf
Size:
8.81 MB
Format:
Adobe Portable Document Format