Constructive Near-Field Interference Effect in a Birdcage MRI Coil with an Artificial Magnetic Shield

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorLezhennikova, Kseniiaen_US
dc.contributor.authorAbdeddaim, Redhaen_US
dc.contributor.authorHurshkainen, Annaen_US
dc.contributor.authorVignaud, A.en_US
dc.contributor.authorDubois, Marie-Claudeen_US
dc.contributor.authorJomin, P.en_US
dc.contributor.authorBerrahou, D.en_US
dc.contributor.authorRaaijmakers, A.en_US
dc.contributor.authorAvdievich, N.en_US
dc.contributor.authorMelchakova, I.V.en_US
dc.contributor.authorEnoch, S.en_US
dc.contributor.authorBelov, P.en_US
dc.contributor.authorSimovski, Konstantinen_US
dc.contributor.authorGlybovski, S.en_US
dc.contributor.departmentDepartment of Electronics and Nanoengineeringen
dc.contributor.groupauthorKostantin Simovski Groupen
dc.contributor.organizationSt. Petersburg National Research University of Information Technologies, Mechanics and Optics (ITMO)en_US
dc.contributor.organizationAix-Marseille Universitéen_US
dc.contributor.organizationUniversité Paris-Saclayen_US
dc.contributor.organizationMultiwave Imagingen_US
dc.contributor.organizationUniversity Medical Center Utrechten_US
dc.contributor.organizationMax Planck Institute for Biological Cyberneticsen_US
dc.date.accessioned2020-06-25T08:37:20Z
dc.date.available2020-06-25T08:37:20Z
dc.date.issued2020-06-02en_US
dc.description| openaire: EC/H2020/736937/EU//M-CUBE
dc.description.abstractRadio-frequency (rf) coils are used in all clinical and research magnetic-resonance-imaging (MRI) systems to excite nuclear spins and to receive signals from them. The quality of imaging depends strongly on the signal-to-noise ratio (SNR) and the transmit efficiency of the coils. The birdcage volume coils used in most MRI scanners for homogeneous imaging of a sample are typically shielded from the external systems of the MRI scanner, i.e., the gradient coils, to confine the rf field within the region of interest. However, the near magnetic field of a conventional copper rf shield surrounding a birdcage coil interferes destructively with the primary field of the coil in the sample, which significantly limits the SNR and the transmit efficiency. In the work presented here, we theoretically study and experimentally demonstrate the possibility of creating an artificial magnetic rf shield for a birdcage coil with constructive interference in a sample. This effect is similar to the in-phase reflection of antenna far fields from a magnetic shield but affects the near field in MRI. We build an analytical model of a birdcage coil shielded with a cylindrical impedance boundary and analyze the conditions for increasing the efficiency of the coil by means of the shield. We conclude that by replacing a copper shield with an artificial magnetic one, it is possible to reduce the dissipative intrinsic losses of the coil and increase the power absorbed by the sample, which improves the efficiency. To demonstrate the effect, we perform a detailed numerical simulation and an experiment with a small birdcage in a 7-T F-19 MRI system with a magnetic shield implemented as a periodic cylindrical metal structure with corrugations filled with a ceramic.en
dc.description.versionPeer revieweden
dc.format.extent14
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationLezhennikova, K, Abdeddaim, R, Hurshkainen, A, Vignaud, A, Dubois, M-C, Jomin, P, Berrahou, D, Raaijmakers, A, Avdievich, N, Melchakova, I V, Enoch, S, Belov, P, Simovski, K & Glybovski, S 2020, 'Constructive Near-Field Interference Effect in a Birdcage MRI Coil with an Artificial Magnetic Shield', Physical Review Applied, vol. 13, no. 6, 064004. https://doi.org/10.1103/PhysRevApplied.13.064004en
dc.identifier.doi10.1103/PhysRevApplied.13.064004en_US
dc.identifier.issn2331-7019
dc.identifier.otherPURE UUID: 3854fb4a-1b4c-4f28-8eff-9db122aa0069en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/3854fb4a-1b4c-4f28-8eff-9db122aa0069en_US
dc.identifier.otherPURE LINK: http://www.scopus.com/inward/record.url?scp=85087544925&partnerID=8YFLogxKen_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/43802173/Lezhennikova_Constructive_near_field_PhysRevApplied.pdfen_US
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/45111
dc.identifier.urnURN:NBN:fi:aalto-202006254068
dc.language.isoenen
dc.publisherAmerican Physical Society
dc.relationinfo:eu-repo/grantAgreement/EC/H2020/736937/EU//M-CUBEen_US
dc.relation.ispartofseriesPhysical Review Applieden
dc.relation.ispartofseriesVolume 13, issue 6en
dc.rightsopenAccessen
dc.subject.keywordimpedanceen_US
dc.subject.keywordsurfacesen_US
dc.subject.keywordantennasen_US
dc.titleConstructive Near-Field Interference Effect in a Birdcage MRI Coil with an Artificial Magnetic Shielden
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files