The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator
dc.contributor | Aalto-yliopisto | fi |
dc.contributor | Aalto University | en |
dc.contributor.author | Saikko, Vesa | |
dc.contributor.author | Ahlroos, Tiina | |
dc.contributor.author | Revitzer, Hannu | |
dc.contributor.author | Ryti, Oskari | |
dc.contributor.author | Kuosmanen, Petri | |
dc.contributor.department | Konetekniikan laitos | fi |
dc.contributor.department | Department of Mechanical Engineering | en |
dc.contributor.department | Kemian laitos | fi |
dc.contributor.department | Department of Chemistry | en |
dc.contributor.school | Insinööritieteiden korkeakoulu | fi |
dc.contributor.school | School of Engineering | en |
dc.contributor.school | Kemian tekniikan korkeakoulu | fi |
dc.contributor.school | School of Chemical Technology | en |
dc.date.accessioned | 2016-04-30T09:01:11Z | |
dc.date.available | 2016-04-30T09:01:11Z | |
dc.date.issued | 2013 | |
dc.description.version | Peer reviewed | en |
dc.format.extent | 70-76 | |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Saikko, Vesa & Ahlroos, Tiina & Revitzer, Hannu & Ryti, Oskari & Kuosmanen, Petri. 2013. The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator. Tribology International. Volume 60. 70-76. ISSN 0301-679X (printed). DOI: 10.1016/j.triboint.2012.10.011. | en |
dc.identifier.doi | 10.1016/j.triboint.2012.10.011 | |
dc.identifier.issn | 0301-679X (printed) | |
dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/20243 | |
dc.identifier.urn | URN:NBN:fi:aalto-201604291892 | |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.relation.ispartofseries | Tribology International | en |
dc.relation.ispartofseries | Volume 60 | |
dc.rights | © 2013 Elsevier. This is the post print version of the following article: Saikko, Vesa & Ahlroos, Tiina & Revitzer, Hannu & Ryti, Oskari & Kuosmanen, Petri. 2013. The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator. Tribology International. Volume 60. 70-76. ISSN 0301-679X (printed). DOI: 10.1016/j.triboint.2012.10.011, which has been published in final form at http://www.sciencedirect.com/science/article/pii/S0301679X12003313. | en |
dc.rights.holder | Elsevier | |
dc.subject.keyword | metal-on-metal | en |
dc.subject.keyword | acetabular cup position | en |
dc.subject.keyword | abduction angle | en |
dc.subject.keyword | edge loading | en |
dc.subject.other | Chemistry | en |
dc.subject.other | Mechanical engineering | en |
dc.title | The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator | en |
dc.type | A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä | fi |
dc.type.dcmitype | text | en |
dc.type.version | Post print | en |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- A1_saikko_vesa_2013.pdf
- Size:
- 2.71 MB
- Format:
- Adobe Portable Document Format