The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorSaikko, Vesa
dc.contributor.authorAhlroos, Tiina
dc.contributor.authorRevitzer, Hannu
dc.contributor.authorRyti, Oskari
dc.contributor.authorKuosmanen, Petri
dc.contributor.departmentKonetekniikan laitosfi
dc.contributor.departmentDepartment of Mechanical Engineeringen
dc.contributor.departmentKemian laitosfi
dc.contributor.departmentDepartment of Chemistryen
dc.contributor.schoolInsinööritieteiden korkeakoulufi
dc.contributor.schoolSchool of Engineeringen
dc.contributor.schoolKemian tekniikan korkeakoulufi
dc.contributor.schoolSchool of Chemical Technologyen
dc.date.accessioned2016-04-30T09:01:11Z
dc.date.available2016-04-30T09:01:11Z
dc.date.issued2013
dc.description.versionPeer revieweden
dc.format.extent70-76
dc.format.mimetypeapplication/pdfen
dc.identifier.citationSaikko, Vesa & Ahlroos, Tiina & Revitzer, Hannu & Ryti, Oskari & Kuosmanen, Petri. 2013. The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator. Tribology International. Volume 60. 70-76. ISSN 0301-679X (printed). DOI: 10.1016/j.triboint.2012.10.011.en
dc.identifier.doi10.1016/j.triboint.2012.10.011
dc.identifier.issn0301-679X (printed)
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/20243
dc.identifier.urnURN:NBN:fi:aalto-201604291892
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesTribology Internationalen
dc.relation.ispartofseriesVolume 60
dc.rights© 2013 Elsevier. This is the post print version of the following article: Saikko, Vesa & Ahlroos, Tiina & Revitzer, Hannu & Ryti, Oskari & Kuosmanen, Petri. 2013. The effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulator. Tribology International. Volume 60. 70-76. ISSN 0301-679X (printed). DOI: 10.1016/j.triboint.2012.10.011, which has been published in final form at http://www.sciencedirect.com/science/article/pii/S0301679X12003313.en
dc.rights.holderElsevier
dc.subject.keywordmetal-on-metalen
dc.subject.keywordacetabular cup positionen
dc.subject.keywordabduction angleen
dc.subject.keywordedge loadingen
dc.subject.otherChemistryen
dc.subject.otherMechanical engineeringen
dc.titleThe effect of acetabular cup position on wear of a large-diameter metal-on-metal prosthesis studied with a hip joint simulatoren
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.dcmitypetexten
dc.type.versionPost printen

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
A1_saikko_vesa_2013.pdf
Size:
2.71 MB
Format:
Adobe Portable Document Format