aalto1 untyped-item.component.html
Investigating sound-field reproduction methods as perceived by bilateral hearing aid users and normal-hearing listeners
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Date
Major/Subject
Mcode
Degree programme
Language
en
Pages
11
Series
Journal of the Acoustical Society of America, Volume 155, issue 2, pp. 1492-1502
Abstract
A perceptual study was conducted to investigate the perceived accuracy of two sound-field reproduction approaches when experienced by hearing-impaired (HI) and normal-hearing (NH) listeners. The methods under test were traditional signal-independent Ambisonics reproduction and a parametric signal-dependent alternative, which were both rendered at different Ambisonic orders. The experiment was repeated in two different rooms: (1) an anechoic chamber, where the audio was delivered over an array of 44 loudspeakers; (2) an acoustically-treated listening room with a comparable setup, which may be more easily constructed within clinical settings. Ten bilateral hearing aid users, with mild to moderate symmetric hearing loss, wearing their devices, and 15 NH listeners were asked to rate the methods based upon their perceived similarity to simulated reference conditions. In the majority of cases, the results indicate that the parametric reproduction method was rated as being more similar to the reference conditions than the signal-independent alternative. This trend is evident for both groups, although the variation in responses was notably wider for the HI group. Furthermore, generally similar trends were observed between the two listening environments for the parametric method. The signal-independent approach was instead rated as being more similar to the reference in the listening room.
Description
Keywords
Other note
Citation
Fernandez, J, McCormack, L, Hyvärinen, P & Kressner, A A 2024, 'Investigating sound-field reproduction methods as perceived by bilateral hearing aid users and normal-hearing listeners', Journal of the Acoustical Society of America, vol. 155, no. 2, pp. 1492-1502. https://doi.org/10.1121/10.0024875