Effect of reflections on 2D tomographic reconstructions of filtered cameras and on interpreting spectroscopic measurements in the JET ITER-like wall divertor

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorKarhunen, J.en_US
dc.contributor.authorCarr, M.en_US
dc.contributor.authorHarrison, J. R.en_US
dc.contributor.authorLomanowski, B.en_US
dc.contributor.authorBalboa, I.en_US
dc.contributor.authorCarvalho, P.en_US
dc.contributor.authorGroth, M.en_US
dc.contributor.authorHuber, A.en_US
dc.contributor.authorMatthews, G. F.en_US
dc.contributor.authorMeakins, A.en_US
dc.contributor.authorSilburn, S.en_US
dc.contributor.departmentDepartment of Applied Physicsen
dc.contributor.groupauthorFusion and Plasma Physicsen
dc.contributor.organizationJETen_US
dc.contributor.organizationUniversity of Lisbonen_US
dc.contributor.organizationForschungszentrum Jülichen_US
dc.contributor.organizationOak Ridge National Laboratoryen_US
dc.date.accessioned2019-11-07T12:09:53Z
dc.date.available2019-11-07T12:09:53Z
dc.date.embargoinfo:eu-repo/date/embargoEnd/2020-10-14en_US
dc.date.issued2019-10-01en_US
dc.description| openaire: EC/H2020/633053/EU//EUROfusion
dc.description.abstractConsidering reflections from metallic wall surfaces in generation of tomographic reconstructions of the tangentially viewing, visible-range spectroscopic divertor cameras in JET has been observed to yield enhanced spatial accuracy and significant reduction of emission artifacts in experimentally resolved 2D line emission distributions. Neglection of reflections in the tomography process was found to lead to overestimation of the emission near the wall surfaces by up to a factor of 4, as well as to formation of bright emission artifacts between the main emission regions and the wall surfaces, comprising locally up to 50% of the emission. Mimicking divertor spectroscopy measurements by integrating the tomographic reconstructions along vertical lines-of-sight implies that reflections comprise 15%-25% of the observed line-integrated emission peaks. The spatial differences in the reflection contribution between the different lines-of-sight are less pronounced than in the 2D reconstructions due to the dominance of the brightest emission regions through which the spectroscopic lines-of-sight pass. However, postprocessing EDGE2D-EIRENE simulations using the CHERAB code and synthetic spectroscopy suggests a decrease of the spectroscopically inferred divertor electron temperature by up to 75%, when redistribution of the observed light due to reflections is considered.en
dc.description.versionPeer revieweden
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationKarhunen, J, Carr, M, Harrison, J R, Lomanowski, B, Balboa, I, Carvalho, P, Groth, M, Huber, A, Matthews, G F, Meakins, A & Silburn, S 2019, 'Effect of reflections on 2D tomographic reconstructions of filtered cameras and on interpreting spectroscopic measurements in the JET ITER-like wall divertor', Review of Scientific Instruments, vol. 90, no. 10, 103504, pp. 1-11. https://doi.org/10.1063/1.5118885en
dc.identifier.doi10.1063/1.5118885en_US
dc.identifier.issn0034-6748
dc.identifier.issn1089-7623
dc.identifier.otherPURE UUID: f4cf844a-3b75-4bbf-85c2-46ab6732d4c3en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/f4cf844a-3b75-4bbf-85c2-46ab6732d4c3en_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/38292780/1.5118885.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/41192
dc.identifier.urnURN:NBN:fi:aalto-201911076197
dc.language.isoenen
dc.publisherAmerican Institute of Physics
dc.relationinfo:eu-repo/grantAgreement/EC/H2020/633053/EU//EUROfusionen_US
dc.relation.fundinginfoThis work has been carried out within the framework of the EUROfusion Consortium and has received funding from the Euratom research and training programme 2014–2018 and 2019– 2020 under grant agreement No. 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission.
dc.relation.ispartofseriesReview of Scientific Instrumentsen
dc.relation.ispartofseriesVolume 90, issue 10, pp. 1-11en
dc.rightsopenAccessen
dc.titleEffect of reflections on 2D tomographic reconstructions of filtered cameras and on interpreting spectroscopic measurements in the JET ITER-like wall divertoren
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files