Fully inkjet-printed glucose assay fabricated on highly porous pigment coating
Loading...
Access rights
openAccess
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal
View/Open full text file from the Research portal
Other link related to publication
View publication in the Research portal
View/Open full text file from the Research portal
Other link related to publication
Date
2020-05-06
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
Series
Microfluidics and Nanofluidics, Volume 24, issue 6
Abstract
A simple paper-based microfluidic device, fabricated on a highly porous coating consisting of functionalised calcium carbonate (FCC) pigment and a microfibrillated cellulose (MFC) and/or polyvinyl alcohol (PVOH) binder, was developed for glucose detection. Both the hydrophobic patterns, consisting of alkyl ketene dimer (AKD), and the enzyme ink, consisting of glucose oxidase (GOx), horseradish peroxidase (HRP) and an indicator containing 4-aminoantipyrine (4-AAP), and sodium 3,5-dichloro-2-hydroxy-benzenesulphonic acid (DHBS) were inkjet-printed. Multiple coating formulations were tested using two indicators, potassium iodide (KI) and 4-AAP/DHBS, to find the optimal formulation with regard to detection sensitivity and assay stability. Higher binder concentrations increased the enzyme activity, especially in the case of PVOH. Two coatings, containing either solely MFC or both MFC and PVOH were ultimately chosen for the glucose assay experiments. For the assays, a 42 nl volume of buffered enzyme solution, containing a total of 5.04 mU GOx and approximately 1.01 mU HRP, in combination with 4 mM 4-AAP and 8 mM DHBS, was printed, and a 1 µl glucose solution, made up over a range of concentrations, was applied onto the samples to evaluate the response. A good linearity was achieved between detection and glucose concentration between 0.1 and 0.6 mM with both coatings. The assays remained stable for four weeks when stored at − 20 °C. The results show that the functional coated substrates offer a viable alternative to cellulose-based substrates for microfluidic applications enabling the use of small reagent and sample volumes.Description
Keywords
Glucose assay, Highly porous coating, Microfluidic device, Paper microfluidics
Other note
Citation
Jutila , E , Koivunen , R , Bollström , R & Gane , P 2020 , ' Fully inkjet-printed glucose assay fabricated on highly porous pigment coating ' , Microfluidics and Nanofluidics , vol. 24 , no. 6 , 40 . https://doi.org/10.1007/s10404-020-02344-4