Exergo-economic assessment and sensitivity analysis of a solar-driven combined cooling, heating and power system with organic Rankine cycle and absorption heat pump

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorChen, Yuzhuen_US
dc.contributor.authorXu, Jinzhaoen_US
dc.contributor.authorZhao, Dandanen_US
dc.contributor.authorWang, Junen_US
dc.contributor.authorLund, Peter D.en_US
dc.contributor.departmentDepartment of Applied Physicsen
dc.contributor.groupauthorNew Energy Technologiesen
dc.contributor.organizationSoutheast University, Nanjingen_US
dc.date.accessioned2021-06-09T06:55:11Z
dc.date.available2021-06-09T06:55:11Z
dc.date.embargoinfo:eu-repo/date/embargoEnd/2023-05-11en_US
dc.date.issued2021-09-01en_US
dc.descriptionFunding Information: This research has been supported by National Natural Science Foundation of China (Grant No. 51736006 ) and Fundamental Research Funds for the Central Universities . Publisher Copyright: © 2021 Elsevier Ltd Copyright: Copyright 2021 Elsevier B.V., All rights reserved.
dc.description.abstractDistrict energy systems based on renewable resources help to reduce greenhouse-gas emissions and fossil-fuel use. Here, a multi-generation energy system combining cooling, heating, and power is realized by employing organic Rankine cycle (ORC) and absorption heat pump (AHP) technologies, which enable cascading the utilization of solar heat. The AHP can operate steadily providing cooling, heating and hot water from solar thermal and geothermal sources. A modelling approach presented to evaluate the energy, exergy, economic, and exergo-economic performance of the above system. The results show that the AHP could reach a coefficient of performance (COP) between 1.38 and 2.37 depending on the mode of operation. The yearly energy and exergy efficiency of the tri-generation system is 56.5% and 9.6%, respectively. Compared to a separate system, the simple economic payback time of the tri-generation system is 3.5 years. The specific exergo-economic cost of electricity produced is 0.12 $/kWh, whereas the cost of hot water is much higher, or 0.31 $/kWh. The sensitivity analysis performed shows that the inlet and outlet temperatures of the AHP together with the yearly solar irradiance have the highest impact on the performance. This study provides a new direction on cost-effective utilization of renewable sources in district energy systems.en
dc.description.versionPeer revieweden
dc.format.extent17
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationChen, Y, Xu, J, Zhao, D, Wang, J & Lund, P D 2021, ' Exergo-economic assessment and sensitivity analysis of a solar-driven combined cooling, heating and power system with organic Rankine cycle and absorption heat pump ', Energy, vol. 230, 120717 . https://doi.org/10.1016/j.energy.2021.120717en
dc.identifier.doi10.1016/j.energy.2021.120717en_US
dc.identifier.issn0360-5442
dc.identifier.issn1873-6785
dc.identifier.otherPURE UUID: 54a58857-7f41-4214-a639-0c3f50de220den_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/54a58857-7f41-4214-a639-0c3f50de220den_US
dc.identifier.otherPURE LINK: http://www.scopus.com/inward/record.url?scp=85105593730&partnerID=8YFLogxK
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/64503862/SCI_Lund_Exergo_economic_assessment_and_sensitivity_analysis_of_a_solar_driven_combined_cooling.CEBE_A_0038.pdfen_US
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/108021
dc.identifier.urnURN:NBN:fi:aalto-202106097279
dc.language.isoenen
dc.publisherElsevier
dc.relation.ispartofseriesEnergyen
dc.relation.ispartofseriesVolume 230en
dc.rightsopenAccessen
dc.subject.keywordAbsorption heat pumpen_US
dc.subject.keywordCombined coolingen_US
dc.subject.keywordExergo-economic analysisen_US
dc.subject.keywordHeating and poweren_US
dc.subject.keywordMulti-generationen_US
dc.subject.keywordParabolic trough collectorsen_US
dc.subject.keywordSensitivity analysisen_US
dc.titleExergo-economic assessment and sensitivity analysis of a solar-driven combined cooling, heating and power system with organic Rankine cycle and absorption heat pumpen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionacceptedVersion

Files