Label-Free Time-Gated Luminescent Detection Method for the Nucleotides with Varying Phosphate Content
| dc.contributor | Aalto-yliopisto | fi |
| dc.contributor | Aalto University | en |
| dc.contributor.author | Kopra, Kari | |
| dc.contributor.author | Seppälä, Tanja | |
| dc.contributor.author | Rabara, Dana | |
| dc.contributor.author | Abreu-Blanco, Maria | |
| dc.contributor.author | Kulmala, Sakari | |
| dc.contributor.author | Holderfield, Matthew | |
| dc.contributor.author | Härmä, Harri | |
| dc.contributor.department | Department of Chemistry and Materials Science | en |
| dc.contributor.groupauthor | Analytical Chemistry | en |
| dc.contributor.organization | University of Turku | |
| dc.contributor.organization | Leidos Inc | |
| dc.date.accessioned | 2018-12-10T10:10:21Z | |
| dc.date.available | 2018-12-10T10:10:21Z | |
| dc.date.issued | 2018-11-16 | |
| dc.description.abstract | A new label-free molecular probe for luminescent nucleotide detection in neutral aqueous solution is presented. Phosphate-containing molecules, such as nucleotides possess vital role in cell metabolism, energy economy, and various signaling processes. Thus, the monitoring of nucleotide concentration and nucleotide related enzymatic reactions is of high importance. Two component lanthanide complex formed from Tb(III) ion carrier and light harvesting antenna, readily distinguishes nucleotides containing different number of phosphates and enable direct detection of enzymatic reactions converting nucleotide triphosphate (NTP) to nucleotide di/monophosphate or the opposite. Developed sensor enables the detection of enzymatic activity with a low nanomolar sensitivity, as highlighted with K-Ras and apyrase enzymes in their hydrolysis assays performed in a high throughput screening compatible 384-well plate format. | en |
| dc.description.version | Peer reviewed | en |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Kopra, K, Seppälä, T, Rabara, D, Abreu-Blanco, M, Kulmala, S, Holderfield, M & Härmä, H 2018, 'Label-Free Time-Gated Luminescent Detection Method for the Nucleotides with Varying Phosphate Content', Sensors, vol. 18, no. 11. https://doi.org/10.3390/s18113989 | en |
| dc.identifier.doi | 10.3390/s18113989 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.other | PURE UUID: 171c7eba-9163-4a75-8645-3cc7d7a45839 | |
| dc.identifier.other | PURE ITEMURL: https://research.aalto.fi/en/publications/171c7eba-9163-4a75-8645-3cc7d7a45839 | |
| dc.identifier.other | PURE FILEURL: https://research.aalto.fi/files/30224565/CHEM_Kopra_et_el_Label_Free_Time_Gated_2018_Sensors.pdf | |
| dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/34928 | |
| dc.identifier.urn | URN:NBN:fi:aalto-201812105943 | |
| dc.language.iso | en | en |
| dc.publisher | MDPI AG | |
| dc.relation.ispartofseries | Sensors | en |
| dc.relation.ispartofseries | Volume 18, issue 11 | en |
| dc.rights | openAccess | en |
| dc.subject.keyword | apyrase | |
| dc.subject.keyword | K-Ras | |
| dc.subject.keyword | label-free | |
| dc.subject.keyword | nucleotide triphosphate | |
| dc.subject.keyword | terbium | |
| dc.title | Label-Free Time-Gated Luminescent Detection Method for the Nucleotides with Varying Phosphate Content | en |
| dc.type | A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä | fi |
| dc.type.version | publishedVersion |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- CHEM_Kopra_et_el_Label_Free_Time_Gated_2018_Sensors.pdf
- Size:
- 1.23 MB
- Format:
- Adobe Portable Document Format