Explicit method to predict annual elevator energy consumption in recurring passenger traffic conditions

Loading...
Thumbnail Image

Access rights

openAccess

URL

Journal Title

Journal ISSN

Volume Title

A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Date

2016-12-01

Major/Subject

Mcode

Degree programme

Language

en

Pages

10
179-188

Series

Journal of Building Engineering, Volume 8

Abstract

This paper proposes a method for simple projecting of annual elevator electricity consumption based on short-term energy measurements and identifies challenges in the determination of actual energy consumption based on kWh meter readings. The study also analyzes the impact of the employed elevator technology, building type, and seasonal variations in elevator usage on the calculation of the annual consumption. Thus, the method can be adopted in different regions with varying elevator usage. The approach employs elevator specific daily energy consumptions measured on the prevailing day types. The reliability of the proposed approach was analyzed and the performance compared to actual measured annual consumption and estimates provided by commonly adopted energy efficiency classification schemes, VDI 4707-1:2009 and ISO 25745-2:2015. The results of the monitored office elevator indicated that the proposed method performs generally better than the competing approaches.

Description

Keywords

Elevators, Energy classification, Energy consumption, Office buildings, Standby consumption, Traffic profile

Other note

Citation

Tukia, T, Uimonen, S, Siikonen, M L, Hakala, H, Donghi, C & Lehtonen, M 2016, ' Explicit method to predict annual elevator energy consumption in recurring passenger traffic conditions ', Journal of Building Engineering, vol. 8, pp. 179-188 . https://doi.org/10.1016/j.jobe.2016.08.004