Comparisons and optimization of two absorption chiller types by considering heat transfer area, exergy, and economy as single objective functions
Loading...
Access rights
openAccess
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
Date
2024-01-06
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
55–65
Series
Clean Energy, Volume 8, issue 1
Abstract
Absorption cooling technology is an environmentally friendly method to generate continuous chilled water making use of multiple thermal sources, such as waste heat and renewable thermal energy. In this study, two absorption chillers (nominal capacity of 400 kW) with series and parallel connections are evaluated. To research the ideal configuration of chillers after thermodynamic analysis, the structures of the chillers are optimized using the particle swarm optimization algorithm by considering the heat transfer area (HTA), exergy efficiency and total annual cost as single-objective functions. The impact of temperature differences between external and internal flows, heat exchanger efficiencies and the solution allocation ratio is estimated. The optimized HTA, coefficient of performance, exergy efficiency and total annual cost are 149.0 m2, 1.56, 29.44% and $229 119 for the series-connected chiller, and 146.7 m2, 1.59, 31.45% and $234 562 for the parallel-connected type, respectively. Under the lowest HTA condition, compared with the reference simulation results, the energy and exergy performances are improved, while the annual total cost is higher. The annual total cost is highest when maximizing the exergy efficiency, which is attributed to the increase in the HTA. The operating cost accounts for 27.42% (series type) and 26.54% (parallel type) when the annual cost is the lowest.Description
Tuhoa kun ilmestyy Clean Energy -lehdessä.
Keywords
Other note
Citation
Qiu, Y, Wang, J, Han, J, Chen, Y, Wang, J & Lund, P 2024, ' Comparisons and optimization of two absorption chiller types by considering heat transfer area, exergy, and economy as single objective functions ', Clean Energy, vol. 8, no. 1, pp. 55–65 . https://doi.org/10.1093/ce/zkad086