Distributed source modeling of intracranial stereoelectro-encephalographic measurements

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorLin, Fa Hsuanen_US
dc.contributor.authorLee, Hsin Juen_US
dc.contributor.authorAhveninen, Jyrkien_US
dc.contributor.authorJääskeläinen, Iiro P.en_US
dc.contributor.authorYu, Hsiang Yuen_US
dc.contributor.authorLee, Cheng Chiaen_US
dc.contributor.authorChou, Chien Chenen_US
dc.contributor.authorKuo, Wen Juien_US
dc.contributor.departmentDepartment of Neuroscience and Biomedical Engineeringen
dc.contributor.organizationUniversity of Torontoen_US
dc.contributor.organizationMassachusetts General Hospitalen_US
dc.contributor.organizationVeterans General Hospital-Taipeien_US
dc.contributor.organizationNational Yang-Ming Universityen_US
dc.date.accessioned2021-02-09T09:05:54Z
dc.date.available2021-02-09T09:05:54Z
dc.date.issued2021-04-15en_US
dc.description.abstractIntracranial stereoelectroencephalography (sEEG) provides unsurpassed sensitivity and specificity for human neurophysiology. However, functional mapping of brain functions has been limited because the implantations have sparse coverage and differ greatly across individuals. Here, we developed a distributed, anatomically realistic sEEG source-modeling approach for within- and between-subject analyses. In addition to intracranial event-related potentials (iERP), we estimated the sources of high broadband gamma activity (HBBG), a putative correlate of local neural firing. Our novel approach accounted for a significant portion of the variance of the sEEG measurements in leave-one-out cross-validation. After logarithmic transformations, the sensitivity and signal-to-noise ratio were linearly inversely related to the minimal distance between the brain location and electrode contacts (slope≈−3.6). The signa-to-noise ratio and sensitivity in the thalamus and brain stem were comparable to those locations at the vicinity of electrode contact implantation. The HGGB source estimates were remarkably consistent with analyses of intracranial-contact data. In conclusion, distributed sEEG source modeling provides a powerful neuroimaging tool, which facilitates anatomically-normalized functional mapping of human brain using both iERP and HBBG data.en
dc.description.versionPeer revieweden
dc.format.extent15
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationLin, F H, Lee, H J, Ahveninen, J, Jääskeläinen, I P, Yu, H Y, Lee, C C, Chou, C C & Kuo, W J 2021, 'Distributed source modeling of intracranial stereoelectro-encephalographic measurements', NeuroImage, vol. 230, 117746. https://doi.org/10.1016/j.neuroimage.2021.117746en
dc.identifier.doi10.1016/j.neuroimage.2021.117746en_US
dc.identifier.issn1053-8119
dc.identifier.issn1095-9572
dc.identifier.otherPURE UUID: 17b48701-ac25-41a2-b86b-bb73a42a9104en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/17b48701-ac25-41a2-b86b-bb73a42a9104en_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/55784031/Lin_Distributed.1_s2.0_S1053811921000239_main.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/102639
dc.identifier.urnURN:NBN:fi:aalto-202102091939
dc.language.isoenen
dc.publisherElsevier
dc.relation.fundinginfoThis study was supported by Natural Sciences and Engineering Research Council of Canada ( RGPIN-2020-05927 ), Ministry of Science and Technology, Taiwan ( 103-2628-B-002-002-MY3 , 105-2221-E-002-104 , 108-2410-H-010 -006 -MY2 , 109-2314-B-075-053 ), National Health Research Institutes ( NHRI-EX108-10727EI , NHRI-EX109-10905NI ), the Academy of Finland (project numbers 138145 and 276643 to IPJ and 298131 to FHL), aivoAALTO project funding of the Aalto University, National Institute on Deafness and other Communication Disorders ( R01DC016765 supported JA, FHL, WJK; R01DC017991 supported JA, IPJ; R01DC016915 supported JA) and Russian Federation Government grant ag. 075-15-2019-1930 to I.P.J.
dc.relation.ispartofseriesNeuroImageen
dc.relation.ispartofseriesVolume 230en
dc.rightsopenAccessen
dc.subject.keywordBrainstemen_US
dc.subject.keywordCross-validationen_US
dc.subject.keywordDynamic statistical parametric mapsen_US
dc.subject.keywordInvasiveen_US
dc.subject.keywordL2-normen_US
dc.subject.keywordMNEen_US
dc.subject.keywordThalamusen_US
dc.titleDistributed source modeling of intracranial stereoelectro-encephalographic measurementsen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Lin_Distributed.1_s2.0_S1053811921000239_main.pdf
Size:
5.9 MB
Format:
Adobe Portable Document Format