Toimistorakennuksen kantavan arinapalkiston jatkuvan sortuman hallinta

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.advisorValjus, Juha
dc.contributor.authorLuck, Krista
dc.contributor.schoolInsinööritieteiden korkeakoulufi
dc.contributor.supervisorPuttonen, Jari
dc.date.accessioned2016-11-02T09:22:55Z
dc.date.available2016-11-02T09:22:55Z
dc.date.issued2016-10-17
dc.description.abstractDiplomityössä tutkittiin vaihtoehtoisen kuormansiirtoreitin menetelmän soveltamista toimistorakennuksen kantavan arinapalkiston jatkuvan sortuman hallintaan. Menetelmän soveltamista ei ole ohjeistettu eurokoodeissa, eivätkä ohjeet ota huomioon kantavan rakenteen poistumisesta aiheutuvia dynaamisia vaikutuksia rakenteissa. Työn tavoite oli luoda perusteet jatkuvan sortuman hallintaan tilanteisiin, joissa käytetään vaihtoehtoista kuormansiirtoreitin menetelmää. Lisäksi työssä määritettiin dynaamiset suurennuskertoimet tarkasteltavan arinapalkiston kahdelle eri rakenneratkaisulle: teräsristikkoarinalle ja paikallavaletulle jälkijännitetylle betoniarinalle. Tutkimuksen soveltava osa toteutettiin tapaustutkimuksena, joka perustuu tehtyyn kirjallisuusanalyysiin. Rakenteelle suoritettiin sekä staattisia että dynaamisia analyyseja, joissa selvitettiin kantavan rakenteen poistosta aiheutuvat siirtymä- ja voimavasteet rakenteissa. Lisäksi tehtiin yksinkertaisilla rakennemalleilla verifiointi- ja vertailulaskelmia, joilla varmennettiin tuloksia ja vertailtiin eri pilarin poistamisen mallinnustapojen eroja. FEM-laskelmien lisäksi laskettiin käsin epälineaarisen teoriaan pohjautuvat dynaamiset suurennuskertoimet kansainvälisten suunnitteluohjeiden mukaan. Tapaustutkimuksen lineaarisissa dynaamisissa analyyseissa saatiin dynaamisille suurennuskertoimille arvoja 1,05 ja 1,5 väliltä, kun pilarin poistuminen mallinnettiin laskevalla kolmionmallisella impulssikuormalla. Lisäksi vertailulaskennassa huomattiin, että pilarin poistumisen mallinnustapa vaikuttaa dynaamiseen suurennuskertoimeen. Dynaamisiksi suurennuskertoimiksi näistä analyyseistä saatiin betonirakenteille arvo 1,3 ja teräsrakenteille arvo 1,5. Tapaustutkimuksen tuloksien perusteella dynaamiset vaikutukset ovat merkittäviä, kun käytetään vaihtoehtoisen kuormansiirtoreitin menetelmää. Siten dynaamiset vaikutukset tulisi ottaa suunnittelussa huomioon. Jatkotutkimuksissa kannattaa selvittää, miten dynaamista suurennuskerrointa voidaan arvioida mahdollisimman tarkoituksen mukaisesti ja varmasti, jotta rakenteille saataisiin riittävä varmuustaso jatkuvaa sortumaa vastaan.fi
dc.description.abstractThis master’s thesis studied the use of the alternate path method to prevent the progressive collapse of beam-stiffened horizontal diagrams in an office building. The Eurocode does not give detailed advice on how to apply the alternate path method in structural design or how to address possible dynamic effects related to the collapse. This study aimed to develop recommendations for designing capacity against progressive collapse with the alternate path method. In addition, the aim of this study was to determine the dynamic amplification factors for two different systems for the horizontal diagrams: a system based on steel truss beams and a system based on post-tensioned cast-in-place concrete beams. In addition to the literary research, the applied part of the study was performed as a case study. The case study was carried out with a FEM-program and both static and dynamic analyses were performed to obtain the forces and deformations in the structure. In addition, calculations were preformed to verify the results received from of the FEM-calculations and to compare different simulation methods for the column removal. Analytical calculations based on nonlinear theory were performed to define the dynamic amplification factors according to U.S. design guidelines. The dynamic amplification factors that were obtained from the linear dynamic analyses ranged between 1.05 and 1.5, when the removal of the column was modeled as a descending triangular impulse load. In addition, it was acknowledged that the simulation method used for the column removal affected the dynamic amplification factor. As a result, a dynamic amplification factor of 1.3 was obtained for the concrete beams and a factor of 1.5 for the steel truss beams. Based on the results of the case study, dynamic effects are significant, when applying the alternate path method. Therefore, dynamic effects should be considered in structural design. In future studies, it might be useful to study further the estimation of the magnitude of the dynamic amplification factor to find reasonable methods for guaranteeing a sufficient confidence level against progressive collapse.en
dc.format.extent78+13
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/23199
dc.identifier.urnURN:NBN:fi:aalto-201611025300
dc.language.isofien
dc.programmeRakenne- ja rakennustuotantotekniikan koulutusohjelmafi
dc.programme.majorRakennetekniikkafi
dc.programme.mcodeR3001fi
dc.rights.accesslevelopenAccess
dc.subject.keyworddynaaminen suurennuskerroinfi
dc.subject.keywordvaihtoehtoinen kuormansiirtoreittifi
dc.subject.keywordjatkuva sortumafi
dc.subject.keywordlineaarinen dynaaminen analyysifi
dc.titleToimistorakennuksen kantavan arinapalkiston jatkuvan sortuman hallintafi
dc.titlePreventing the progressive collapse of beam-stiffened horizontal diagrams in an office buildingen
dc.typeG2 Pro gradu, diplomityöfi
dc.type.okmG2 Pro gradu, diplomityö
dc.type.ontasotMaster's thesisen
dc.type.ontasotDiplomityöfi
dc.type.publicationmasterThesis
local.aalto.idinssi54832
local.aalto.inssiarchivenr4626
local.aalto.inssilocationP1 Ark Aalto
local.aalto.openaccessyes

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
master_Luck_Krista_2016.pdf
Size:
5.18 MB
Format:
Adobe Portable Document Format