Enhancing industrial X-ray tomography by data-centric statistical methods
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Date
Major/Subject
Mcode
Degree programme
Language
en
Pages
17
Series
Data-Centric Engineering, Volume 1, issue 3
Abstract
X-ray tomography has applications in various industrial fields such as sawmill industry, oil and gas industry, as well as chemical, biomedical, and geotechnical engineering. In this article, we study Bayesian methods for the X-ray tomography reconstruction. In Bayesian methods, the inverse problem of tomographic reconstruction is solved with the help of a statistical prior distribution which encodes the possible internal structures by assigning probabilities for smoothness and edge distribution of the object. We compare Gaussian random field priors, that favor smoothness, to non-Gaussian total variation (TV), Besov, and Cauchy priors which promote sharp edges and high-and low-contrast areas in the object. We also present computational schemes for solving the resulting high-dimensional Bayesian inverse problem with 100,000-1,000,000 unknowns. We study the applicability of a no-U-turn variant of Hamiltonian Monte Carlo (HMC) methods and of a more classical adaptive Metropolis-within-Gibbs (MwG) algorithm to enable full uncertainty quantification of the reconstructions. We use maximum a posteriori (MAP) estimates with limited-memory BFGS (Broyden-Fletcher-Goldfarb-Shanno) optimization algorithm. As the first industrial application, we consider sawmill industry X-ray log tomography. The logs have knots, rotten parts, and even possibly metallic pieces, making them good examples for non-Gaussian priors. Secondly, we study drill-core rock sample tomography, an example from oil and gas industry. In that case, we compare the priors without uncertainty quantification. We show that Cauchy priors produce smaller number of artefacts than other choices, especially with sparse high-noise measurements, and choosing HMC enables systematic uncertainty quantification, provided that the posterior is not pathologically multimodal or heavy-tailed.Description
Funding Information: This work has been funded by Academy of Finland (project numbers 326240, 326341, 314474, 321900, 313708) and by European Regional Development Fund (ARKS project A74305). Publisher Copyright: © The Author(s), 2020.
Other note
Citation
Suuronen, J, Emzir, M, Lasanen, S, Särkkä, S & Roininen, L 2020, 'Enhancing industrial X-ray tomography by data-centric statistical methods', Data-Centric Engineering, vol. 1, no. 3, e10. https://doi.org/10.1017/dce.2020.10