Laser-Doppler anemometer measurements of air flow between cooling ribs of an electrical motor

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorSaari, Kari
dc.contributor.departmentSovelletun termodynamiikan laboratoriofi
dc.contributor.departmentLaboratory of Applied Thermodynamicsen
dc.contributor.schoolTeknillinen korkeakoulufi
dc.contributor.schoolHelsinki University of Technologyen
dc.date.accessioned2016-12-13T10:02:32Z
dc.date.available2016-12-13T10:02:32Z
dc.date.issued2004
dc.descriptionMEMO No CFD/THERMO-45-2004 DATE: 2nd February 2004
dc.description.abstractAbstract: Two dimensional air flow velocities and turbulence parameters between cooling ribs of an electrical motor were measured using a laser-Doppler anemometer. Both the electrical motor and the air flow between the cooling ribs were approximately at the ambient temperature. Main result: The axial air velocity decreases substantially from 19 m/s to 8...9 m/s while flowing through the cooling rib channel. Also the kinetic energy of turbulence has a rapid decrease along the flow channel.en
dc.format.extent23
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/23728
dc.identifier.urnURN:NBN:fi:aalto-201612135909
dc.language.isoenen
dc.publisherAalto Universityen
dc.publisherAalto-yliopistofi
dc.subject.keywordcooling riben
dc.subject.keywordelectrical motoren
dc.subject.keywordlaser-Doppler anemometeren
dc.subject.keywordvelocity, turbulenceen
dc.subject.otherMechanical engineeringen
dc.titleLaser-Doppler anemometer measurements of air flow between cooling ribs of an electrical motoren