Performance comparison between optimized design of a centralized and semi-decentralized community size solar district heating system

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorRehman, Hassam uren_US
dc.contributor.authorHirvonen, Janneen_US
dc.contributor.authorSirén, Kaien_US
dc.contributor.departmentDepartment of Energy and Mechanical Engineeringen
dc.contributor.groupauthorEnergy efficiency and systemsen
dc.date.accessioned2019-05-06T09:13:18Z
dc.date.available2019-05-06T09:13:18Z
dc.date.embargoinfo:eu-repo/date/embargoEnd/2020-08-24en_US
dc.date.issued2018-11-01en_US
dc.description.abstractSolar thermal energy is widely recognized as one of the most important renewable energy resources. However, in high latitudes, due to various climatic and mismatch challenges, such solar district heating networks are difficult to implement. The objective of the paper is to optimize and compare two different design layouts and control strategies for solar district heating systems in Finnish conditions. The two different designs proposed are a centralized and a semi-decentralized solar district heating system. The centralized system consists of two centralized short-term tanks operating at different temperature levels charged by a solar collector and heat pumps. Borehole thermal energy storage is also charged via these two centralized tanks. In contrast, the semi-decentralized system consists of one centralized low temperature tank charged by a solar collector and a borehole thermal energy storage and decentralized high temperature tank charged by an individual heat pump in each house. In this case, borehole thermal energy storage is charged only by the centralized warm tank. These systems are designed using the dynamic simulation software TRNSYS for Finnish conditions. Later on, multi-objective optimization is carried out with a genetic algorithm using the MOBO (Multi-objective building optimizer) optimization tool, where two objectives, i.e. purchased electricity and life cycle costs, are minimized. Various design variables are considered, which included both component sizes and control parameters as inputs to the optimization. The optimization results show that in terms of life cycle cost and purchased electricity, the decentralized system clearly outperforms the centralized system. With a similar energy performance, the reduction in life cycle cost is up to 35% for the decentralized system. Both systems can achieve close to 90% renewable energy fraction. These systems are also sensitive to the prices. Furthermore, the results show that the solar thermal collector area and seasonal storage volume can be reduced in a decentralized system to reduce the cost compared to a centralized system. The losses in the centralized system are 40–12% higher compared to the decentralized system. The results also show that in both systems, high performance is achieved when the borehole storage is wider with less depth, as it allows better direct utilization of seasonally stored heat. The system layout and controls varied the performance and life cycle cost; therefore it is essential to consider these when implementing such systems.en
dc.description.versionPeer revieweden
dc.format.extent23
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationRehman, H U, Hirvonen, J & Sirén, K 2018, 'Performance comparison between optimized design of a centralized and semi-decentralized community size solar district heating system', Applied Energy, vol. 229, pp. 1072-1094. https://doi.org/10.1016/j.apenergy.2018.08.064en
dc.identifier.doi10.1016/j.apenergy.2018.08.064en_US
dc.identifier.issn0306-2619
dc.identifier.issn1872-9118
dc.identifier.otherPURE UUID: 687f8b87-b1c7-485a-bfe1-8be8d1054fdden_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/687f8b87-b1c7-485a-bfe1-8be8d1054fdden_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/32946908/Performance_comparison_between_optimized_design_of_a_centralized_and_semi_decentralized_community_size_solar_district_heating_system_Hassam_ur_Rehman.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/37683
dc.identifier.urnURN:NBN:fi:aalto-201905062803
dc.language.isoenen
dc.publisherElsevier
dc.relation.fundinginfoThis work was supported by the Academy of Finland – Finland, grant number: 284977 , under the New Energy research program.
dc.relation.ispartofseriesApplied Energyen
dc.relation.ispartofseriesVolume 229, pp. 1072-1094en
dc.rightsopenAccessen
dc.subject.keywordCentralized solar districten_US
dc.subject.keywordCold climateen_US
dc.subject.keywordDecentralized solar districten_US
dc.subject.keywordMulti-objective optimizationen_US
dc.subject.keywordSeasonal storageen_US
dc.subject.keywordSolar communityen_US
dc.titlePerformance comparison between optimized design of a centralized and semi-decentralized community size solar district heating systemen