Elucidating the Capabilities of Mirrorless Large Core Bundled Plastic Fiber Optic Displacement Sensor for Paracetamol Detection

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorZulkifli, Mohd Zamani
dc.contributor.authorAzri, Muhammad Fadhli Mohd
dc.contributor.authorYusof, Muhammad Khudhori Mohd
dc.contributor.authorShafiee, Saiful Arifin
dc.contributor.authorSabere, Awis Sukarni Mohmad
dc.contributor.authorYao, Lau Kuen
dc.contributor.authorSamsudin, Sani Amril
dc.contributor.authorBahari, Muhammad Syahril
dc.contributor.authorYasin, Moh
dc.contributor.departmentInternational Islamic University Malaysia
dc.contributor.departmentDepartment of Electronics and Nanoengineering
dc.contributor.departmentUniversiti Teknologi Malaysia
dc.contributor.departmentUniversiti Malaysia Perlis
dc.contributor.departmentUniversitas Airlangga
dc.date.accessioned2021-08-11T08:47:59Z
dc.date.available2021-08-11T08:47:59Z
dc.date.issued2021
dc.descriptionPublisher Copyright: © 2021 Mohd Zamani Zulkifli et al.
dc.description.abstractA simple mirrorless plastic optical fiber displacement sensor was used to determine the concentration of paracetamol (PCM) in an aqueous solution. Paracetamol concentrations between 5 and 45 ppm were tested by the proposed sensor. With a mirror, the substantial sensitivity observed by an output power changed against displacement of 0.0403 mW/μm for the front slope and 0.023 mW/μm for the back slope with linearities of more than 99%. On the other hand, nonmirror reflector showed a sensitivity of 0.0006 mW/μm for the front slope and 0.0002 mW/μm for the back slope for the case of a red reflector and a sensitivity of 0.0007 mW/μm and 0.0003 mW/μm for the front and the back slope, respectively, for the case of a white reflector. The sensor sensitivity for the red and white coloured papers, which were used as the nonmirror reflectors and the mirror reflector itself against changing PCM concentrations, was 0.0004 mW/ppm, 0.0008 mW/ppm, and 0.02 mW/ppm, respectively. The experimental results indicated that the sensor was not only able to detect and measure the concentration of PCM in aqueous solutions but was also very stable with the additional advantages of a cost-effective and practical design that is highly beneficial for real-world sensing applications.en
dc.description.versionPeer revieweden
dc.format.extent16
dc.format.mimetypeapplication/pdf
dc.identifier.citationZulkifli , M Z , Azri , M F M , Yusof , M K M , Shafiee , S A , Sabere , A S M , Yao , L K , Samsudin , S A , Bahari , M S & Yasin , M 2021 , ' Elucidating the Capabilities of Mirrorless Large Core Bundled Plastic Fiber Optic Displacement Sensor for Paracetamol Detection ' , JOURNAL OF SENSORS , vol. 2021 , 6625780 . https://doi.org/10.1155/2021/6625780en
dc.identifier.doi10.1155/2021/6625780
dc.identifier.issn1687-725X
dc.identifier.issn1687-7268
dc.identifier.otherPURE UUID: ca6dfd44-8af2-449c-96a6-c7e262d304ef
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/ca6dfd44-8af2-449c-96a6-c7e262d304ef
dc.identifier.otherPURE LINK: http://www.scopus.com/inward/record.url?scp=85111015281&partnerID=8YFLogxK
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/66450864/6625780.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/109076
dc.identifier.urnURN:NBN:fi:aalto-202108118316
dc.language.isoenen
dc.publisherHindawi Publishing Corporation
dc.relation.ispartofseriesJOURNAL OF SENSORSen
dc.relation.ispartofseriesVolume 2021en
dc.rightsopenAccessen
dc.titleElucidating the Capabilities of Mirrorless Large Core Bundled Plastic Fiber Optic Displacement Sensor for Paracetamol Detectionen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion
Files