Development of primary reference facilities and measurement comparison of standard artifacts for the bidirectional transmittance distribution function

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorFu, J.en_US
dc.contributor.authorQuast, T.en_US
dc.contributor.authorVelke, E.en_US
dc.contributor.authorEsslinger, M.en_US
dc.contributor.authorPastuschek, M.en_US
dc.contributor.authorSchirmacher, A.en_US
dc.contributor.authorAschan, R.en_US
dc.contributor.authorManoocheri, F.en_US
dc.contributor.authorIkonen, E.en_US
dc.contributor.departmentDepartment of Signal Processing and Acousticsen
dc.contributor.departmentDepartment of Information and Communications Engineeringen
dc.contributor.groupauthorMetrology Research Instituteen
dc.contributor.organizationPhysikalisch-Technische Bundesanstalten_US
dc.date.accessioned2023-08-30T04:19:25Z
dc.date.available2023-08-30T04:19:25Z
dc.date.issued2023-08-01en_US
dc.descriptionFunding Information: The BxDiff project (Grant No. JRP 18SIB03) has received funding from the EMPIR program co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation program. J.F. gratefully acknowledges the support of the Braunschweig International Graduate School of Metrology B-IGSM. Publisher Copyright: © 2023 Author(s).
dc.description.abstractTo determine the bidirectional transmittance distribution function (BTDF) of diffusely transmitting materials, two new primary facilities have been developed at the Physikalisch-Technische Bundesanstalt (PTB) and Aalto University (Aalto). A detailed description of both facilities and the different approaches used are presented in this paper. The performance of both facilities is compared by determining the BTDF of two different diffuser types in both in-plane and out-of-plane bidirectional geometries at four different wavelengths in the visible spectral range. Due to delayed completion of PTB’s primary facility, the measured BTDF values are compared between Aalto’s primary facility and another PTB setup, whose measurement scales are successfully transferred to PTB’s primary facility by an internal comparison. A thorough analysis of the measurement uncertainty is presented, leading to a combined k = 1 standard uncertainty of 0.8%-1.2% for PTB’s primary facility and 1.3%-1.7% for Aalto’s primary facility. The BTDF results obtained agree well within their expanded k = 2 uncertainty. This indirect bilateral comparison shows that Aalto’s and PTB’s new facilities are suited as primary reference setups for the determination of the BTDF. These studies also reveal action points to improved measurement capabilities and for a reduction of the measurement uncertainty, depending on the type of diffuser under test.en
dc.description.versionPeer revieweden
dc.format.extent9
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationFu, J, Quast, T, Velke, E, Esslinger, M, Pastuschek, M, Schirmacher, A, Aschan, R, Manoocheri, F & Ikonen, E 2023, ' Development of primary reference facilities and measurement comparison of standard artifacts for the bidirectional transmittance distribution function ', Review of Scientific Instruments, vol. 94, no. 8, 083102 . https://doi.org/10.1063/5.0151803en
dc.identifier.doi10.1063/5.0151803en_US
dc.identifier.issn0034-6748
dc.identifier.issn1089-7623
dc.identifier.otherPURE UUID: 0c9a1df0-c3e3-46cf-92a2-290b465dbad2en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/0c9a1df0-c3e3-46cf-92a2-290b465dbad2en_US
dc.identifier.otherPURE LINK: http://www.scopus.com/inward/record.url?scp=85168108251&partnerID=8YFLogxKen_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/119656003/Sharma_2023_Metrologia_60_055004.pdfen_US
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/122952
dc.identifier.urnURN:NBN:fi:aalto-202308305292
dc.language.isoenen
dc.publisherAmerican Institute of Physics
dc.relation.ispartofseriesReview of Scientific Instrumentsen
dc.relation.ispartofseriesVolume 94, issue 8en
dc.rightsopenAccessen
dc.titleDevelopment of primary reference facilities and measurement comparison of standard artifacts for the bidirectional transmittance distribution functionen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files