Lightning Over-voltages in Nuclear Power Plants
| dc.contributor | Aalto-yliopisto | fi |
| dc.contributor | Aalto University | en |
| dc.contributor.author | Gurbuz, Ismet Tuna | en_US |
| dc.contributor.author | Lehtonen, Matti | en_US |
| dc.contributor.author | Belahcen, Anouar | en_US |
| dc.contributor.department | Department of Electrical Engineering and Automation | en |
| dc.contributor.groupauthor | Computational Electromechanics | en |
| dc.contributor.groupauthor | Power Systems and High Voltage Engineering | en |
| dc.date.accessioned | 2020-07-03T11:07:29Z | |
| dc.date.available | 2020-07-03T11:07:29Z | |
| dc.date.issued | 2019-08 | en_US |
| dc.description.abstract | When lightning strikes to the transmission towers, the equipment and the network components are jeopardized by the over-voltages. If the over-voltage magnitudes are more than the basic insulation level (BIL) of the equipment, irreversible damages occur in the system. This paper analyzes lightning over-voltages in two different nuclear power plants (NPP) by applicable modeling and simulations. In order to keep the over-voltage magnitudes below BILs of the equipment, protection ways are proposed with the surge arresters and the surge capacitances. | en |
| dc.description.version | Peer reviewed | en |
| dc.format.extent | 2 | |
| dc.format.mimetype | application/pdf | en_US |
| dc.identifier.citation | Gurbuz, I T, Lehtonen, M & Belahcen, A 2019, Lightning Over-voltages in Nuclear Power Plants. in Proceedings of the 19th International Symposium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering, ISEF 2019., 9096989, IEEE, International Symposium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering, Nancy, France, 29/08/2019. https://doi.org/10.1109/ISEF45929.2019.9096989 | en |
| dc.identifier.doi | 10.1109/ISEF45929.2019.9096989 | en_US |
| dc.identifier.isbn | 9781728115603 | |
| dc.identifier.other | PURE UUID: 8db80219-1614-4431-8809-9f74d1c354ec | en_US |
| dc.identifier.other | PURE ITEMURL: https://research.aalto.fi/en/publications/8db80219-1614-4431-8809-9f74d1c354ec | en_US |
| dc.identifier.other | PURE FILEURL: https://research.aalto.fi/files/43832441/ELEC_Gurbuz_etal_Lightning_Over_voltages_ISEF2019_authoracceptedmanuscript.pdf | |
| dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/45322 | |
| dc.identifier.urn | URN:NBN:fi:aalto-202007034279 | |
| dc.language.iso | en | en |
| dc.relation.ispartof | International Symposium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering | en |
| dc.relation.ispartofseries | Proceedings of the 19th International Symposium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering, ISEF 2019 | en |
| dc.rights | openAccess | en |
| dc.subject.keyword | Basic Insulation Level | en_US |
| dc.subject.keyword | Lightning | en_US |
| dc.subject.keyword | Nuclear Power Plant | en_US |
| dc.subject.keyword | Over-Voltage | en_US |
| dc.subject.keyword | Surge Arrester | en_US |
| dc.subject.keyword | Surge Capacitance | en_US |
| dc.title | Lightning Over-voltages in Nuclear Power Plants | en |
| dc.type | A4 Artikkeli konferenssijulkaisussa | fi |
| dc.type.version | publishedVersion |