Hygrothermal Behaviour of Ventilation Cavities in Highly Insulated Envelopes

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorViljanen, Klausen_US
dc.contributor.authorLü, Xiaoshuen_US
dc.contributor.authorPuttonen, Jarien_US
dc.contributor.departmentDepartment of Civil Engineeringen
dc.contributor.groupauthorStructures – Structural Engineering, Mechanics and Computationen
dc.date.accessioned2020-08-12T09:11:40Z
dc.date.available2020-08-12T09:11:40Z
dc.date.issued2020-06-30en_US
dc.description.abstractThis article presents long-term experimental studies on the moisture safety in the ventilation cavities of highly insulated (HI) structures. The tested HI-walls had thermal transmittances of 0.11-0.13 W/m2K. A wall with a thermal transmittance of 0.23 W/m2K represented the baseline wall in the test. In addition to walls, an HI-roof of a newly built house with a U-value of 0.08 W/m2K was measured. The results indicate that, in the ventilation cavity, the relative humidity of an HI-wall exceeds 1-7% of the humidity measured from the baseline wall during winter, which coincides with the 0.4-1.5°C lower temperatures observed in the HI-walls. The mold risk in the ventilation cavities of the walls is low, as the value of the mold index (MI) remains below one, which indicates small amounts of microscopic mold only on surfaces. However, at the bottom of the cavity, the MI value reaches 1.4 due to lower temperatures. In the HI-roof, the MI values are between 1.0 and 2.0 in the middle of the cavity in winter. The reasons for the higher mold risk of the roof are the humid weather, the built-in moisture of the roof and the low heat flux from inside. The study confirms that, in the future, warmer weather and increased humidity can increase moisture risks in the ventilation cavities. The results support the use of materials that are more resistant to mold in the outer parts of structures.en
dc.description.versionPeer revieweden
dc.format.extent10
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationViljanen, K, Lü, X & Puttonen, J 2020, 'Hygrothermal Behaviour of Ventilation Cavities in Highly Insulated Envelopes', E3S Web of Conferences, vol. 172, 07003. https://doi.org/10.1051/e3sconf/202017207003en
dc.identifier.doi10.1051/e3sconf/202017207003en_US
dc.identifier.issn2267-1242
dc.identifier.otherPURE UUID: 44a1f234-68de-41dd-89bd-d3588a43d5d7en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/44a1f234-68de-41dd-89bd-d3588a43d5d7en_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/44736144/e3sconf_nsb2020_07003.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/45666
dc.identifier.urnURN:NBN:fi:aalto-202008124680
dc.language.isoenen
dc.publisherEDP Sciences
dc.relation.ispartofseriesE3S Web of Conferencesen
dc.relation.ispartofseriesVolume 172en
dc.rightsopenAccessen
dc.titleHygrothermal Behaviour of Ventilation Cavities in Highly Insulated Envelopesen
dc.typeA4 Artikkeli konferenssijulkaisussafi
dc.type.versionpublishedVersion

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
e3sconf_nsb2020_07003.pdf
Size:
4.74 MB
Format:
Adobe Portable Document Format