Metallic Coulomb blockade thermometry down to 10 mK and below
| dc.contributor | Aalto-yliopisto | fi |
| dc.contributor | Aalto University | en |
| dc.contributor.author | Casparis, L. | |
| dc.contributor.author | Meschke, M. | |
| dc.contributor.author | Maradan, D. | |
| dc.contributor.author | Clark, A. C. | |
| dc.contributor.author | Scheller, C. P. | |
| dc.contributor.author | Schwarzwälder, K. K. | |
| dc.contributor.author | Pekola, Jukka P. | |
| dc.contributor.author | Zumbühl, D. M. | |
| dc.contributor.department | Department of Applied Physics | en |
| dc.contributor.department | Teknillisen fysiikan laitos | fi |
| dc.contributor.school | Perustieteiden korkeakoulu | fi |
| dc.contributor.school | School of Science | en |
| dc.date.accessioned | 2015-05-29T09:01:00Z | |
| dc.date.available | 2015-05-29T09:01:00Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | We present an improved nuclear refrigerator reaching 0.3 mK, aimed at microkelvin nanoelectronic experiments, and use it to investigate metallic Coulomb blockadethermometers (CBTs) with various resistances R. The high-R devices cool to slightly lower T, consistent with better isolation from the noise environment, and exhibit electron-phonon cooling ∝ T 5 and a residual heat-leak of 40 aW. In contrast, the low-R CBTs display cooling with a clearly weaker T-dependence, deviating from the electron-phonon mechanism. The CBTs agree excellently with the refrigerator temperature above 20 mK and reach a minimum-T of 7.5 ± 0.2 mK. | en |
| dc.description.version | Peer reviewed | en |
| dc.format.extent | 083903/1-3 | |
| dc.format.mimetype | application/pdf | en |
| dc.identifier.citation | Casparis, L. & Meschke, M. & Maradan, D. & Clark, A. C. & Scheller, C. P. & Schwarzwälder, K. K. & Pekola, Jukka & Zumbühl, D. M. 2012. Metallic Coulomb blockade thermometry down to 10 mK and below. Review of Scientific Instruments. Volume 83, Issue 8. 083903/1-3. ISSN 0034-6748 (printed). DOI: 10.1063/1.4744944. | en |
| dc.identifier.doi | 10.1063/1.4744944 | |
| dc.identifier.issn | 0034-6748 (printed) | |
| dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/16393 | |
| dc.identifier.urn | URN:NBN:fi:aalto-201505293041 | |
| dc.language.iso | en | en |
| dc.publisher | AIP Publishing | en |
| dc.relation.ispartofseries | Review of Scientific Instruments | en |
| dc.relation.ispartofseries | Volume 83, Issue 8 | |
| dc.rights | © 2012 AIP Publishing. This is the accepted version of the following article: Casparis, L. & Meschke, M. & Maradan, D. & Clark, A. C. & Scheller, C. P. & Schwarzwälder, K. K. & Pekola, Jukka & Zumbühl, D. M. 2012. Metallic Coulomb blockade thermometry down to 10 mK and below. Review of Scientific Instruments. Volume 83, Issue 8. 083903/1-3. ISSN 0034-6748 (printed). DOI: 10.1063/1.4744944, which has been published in final form at http://scitation.aip.org/content/aip/journal/rsi/83/8/10.1063/1.4744944 | en |
| dc.rights.holder | AIP Publishing | |
| dc.subject.keyword | Coulomb blockade | en |
| dc.subject.keyword | refrigeration | en |
| dc.subject.keyword | refrigerators | en |
| dc.subject.keyword | thermometers | en |
| dc.subject.keyword | copper | en |
| dc.subject.keyword | demagnetization | en |
| dc.subject.keyword | nanowires | en |
| dc.subject.other | Physics | en |
| dc.title | Metallic Coulomb blockade thermometry down to 10 mK and below | en |
| dc.type | A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä | fi |
| dc.type.dcmitype | text | en |
| dc.type.version | Final published version | en |
Files
Original bundle
1 - 1 of 1