Absolute measurement methods for reflectance and fluorescence

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorHolopainen, Silja
dc.contributor.departmentSignaalinkäsittelyn ja akustiikan laitosfi
dc.date.accessioned2012-08-23T05:19:42Z
dc.date.available2012-08-23T05:19:42Z
dc.date.issued2009
dc.description.abstractReflectance and fluorescence are important properties when determining the colour and appearance of solid opaque material. They are also useful in several other industrial applications such as those in biochemical and medical industry and in remote sensing. In most industrial applications, the reflectance and / or fluorescence characteristics of samples are measured relative to a known reference standard. The uncertainty of the measurements is naturally dependent on the uncertainty of the reference standard and therefore it is vital to have high-accuracy calibration instruments capable of absolute measurements. In addition, the standards should be calibrated in the same measurement geometry as the application where they are used. Particularly, instruments capable of absolute fluorescence measurements commonly use a fixed measurement geometry and therefore there is a need for an instrument that does not have this limitation. In the thesis, goniometric measurement facilities for measuring reflectance and fluorescence characteristics of reference standards have been designed and developed. The significance of light scattering in goniometric diffuse reflectance measurements has been studied. The effect can cause errors of the order of 1 % in the measurements if it is not properly taken into account. Also, this effect may be at least partly responsible for the discrepancies reported earlier between goniometric and integrating-sphere-based diffuse reflectance measurements. The wavelength range of an existing gonioreflectometer for calibrating reflectance and radiance factors has been extended and an extensive bilateral comparison in the wavelength range 250 nm - 1650 nm is reported. Such extensive comparisons between goniometric instruments are very rare even though it is the only way to verify the reliability of the absolute scales in National Metrology Institutes. A goniofluorometer has been designed and developed for measuring bispectral luminescent radiance factors in various measurement geometries. Also, the theory and mathematics of a new method for measuring absolute fluorescence quantum yield based on goniometric measurements has been derived. One of the most significant results of this thesis is the discovery of non-Lambertian behaviour of fluorescence emission from solid amorphous material. In addition, it has been observed that the angular pattern of fluorescence emission is not very tightly linked to the angular pattern of reflectance. This is an important result since most commercial and research instruments are only capable of measurements in a fixed geometry and usually rely on the assumption of Lambertian emission of fluorescence.en
dc.format.extentVerkkokirja (513 KB, 52 s.)
dc.format.mimetypeapplication/pdf
dc.identifier.isbn978-951-22-9898-3
dc.identifier.isbn978-951-22-9897-6 (printed)#8195;
dc.identifier.issn1795-4584
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/4623
dc.identifier.urnURN:ISBN:978-951-22-9898-3
dc.language.isoenen
dc.publisherTeknillinen korkeakouluen
dc.relation.haspart[Publication 1]: Silja Holopainen, Farshid Manoocheri, Saulius Nevas, and Erkki Ikonen. 2007. Effect of light scattering from source optics in goniometric diffuse reflectance measurements. Metrologia, volume 44, number 3, pages 167-170. © 2007 Institute of Physics Publishing. By permission.en
dc.relation.haspart[Publication 2]: Silja Holopainen, Farshid Manoocheri, Erkki Ikonen, Kai-Olaf Hauer, and Andreas Höpe. 2009. Comparison measurements of 0 : 45 radiance factor and goniometrically determined diffuse reflectance. Applied Optics, volume 48, number 15, pages 2947-2957. © 2009 Optical Society of America (OSA). By permission.en
dc.relation.haspart[Publication 3]: Silja Holopainen, Farshid Manoocheri, and Erkki Ikonen. 2008. Goniofluorometer for characterization of fluorescent materials. Applied Optics, volume 47, number 6, pages 835-842; volume 47, number 36, page 6880. © 2008 Optical Society of America (OSA). By permission.en
dc.relation.haspart[Publication 4]: Silja Holopainen, Farshid Manoocheri, and Erkki Ikonen. 2009. Non-Lambertian behaviour of fluorescence emission from solid amorphous material. Metrologia, volume 46, number 4, pages S197-S201. © 2009 by authors and © 2009 Institute of Physics Publishing. By permission.en
dc.relation.haspart[Errata file]: Errata of publication 3en
dc.relation.ispartofseriesTKK dissertations, 166en
dc.subject.keyworddiffuse reflectanceen
dc.subject.keywordradiance factoren
dc.subject.keywordbispectral luminescent radiance factoren
dc.subject.keywordfluorescence quantum yielden
dc.subject.otherElectrical engineeringen
dc.titleAbsolute measurement methods for reflectance and fluorescenceen
dc.typeG5 Artikkeliväitöskirjafi
dc.type.dcmitypetexten
dc.type.ontasotVäitöskirja (artikkeli)fi
dc.type.ontasotDoctoral dissertation (article-based)en
local.aalto.digiauthask
local.aalto.digifolderAalto_67654
Files
Original bundle
Now showing 1 - 6 of 6
No Thumbnail Available
Name:
isbn9789512298983.pdf
Size:
500.58 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
publication1.pdf
Size:
149.29 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
publication2.pdf
Size:
1.54 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
publication3.pdf
Size:
551.96 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
publication4.pdf
Size:
274.37 KB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
errata_of_publication_P3.pdf
Size:
87.37 KB
Format:
Adobe Portable Document Format