Experimental study on combustion parameters and temperature distribution of linear fire under different oxygen concentration in tunnel
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Authors
Date
2021-09
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
10
Series
Results in engineering, Volume 11
Abstract
Many cables are placed in the underground utility tunnel, which are with greater fire hazards. Once fire occurs in an enclosed tunnel, thermal radiation may ignite the adjacent cables, which will cause cable fire and further expanding of fire scale, and oxygen will be consumed over time. Thus, it's important to investigate cable fire under low oxygen concentration. In this paper, a fire experiment has carried out in a reduced-scale enclosed tunnel with different heights of linear fire near the side wall. The combustion parameters, as well as transverse temperature distribution and maximum ceiling temperature rise under different oxygen concentration are investigated. Based on oxygen consumption calorimetry, the combustion efficiency and heat release rate of each fire source can be obtained. And two formulas to predict transverse temperature distribution and temperature rise under ceiling are proposed based on dimensionless analysis. Results show that different combustion parameters changing under varies oxygen concentrations, two temperature peaks exist in the cross section and the highest temperature is directly above the fire source. Conclusions are given to provide references in fire protection work in utility tunnel.Description
Keywords
Combustion parameters, Oxygen concentration, Linear fire source, Transverse temperature distribution, Maximum ceiling temperature rise, FLAME CHARACTERISTICS, GAS TEMPERATURE, VENTILATION, BENEATH