Bolometer operating at the threshold for circuit quantum electrodynamics

No Thumbnail Available
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal

Other link related to publication
Date
2020-10-01
Major/Subject
Mcode
Degree programme
Language
en
Pages
47–51
Series
Nature, Volume 586, issue 7827
Abstract
Radiation sensors based on the heating effect of absorbed radiation are typically simple to operate and flexible in terms of input frequency, so they are widely used in gas detection, security, terahertz imaging, astrophysical observations and medical applications. Several important applications are currently emerging from quantum technology and especially from electrical circuits that behave quantum mechanically, that is, circuit quantum electrodynamics. This field has given rise to single-photon microwave detectors and a quantum computer that is superior to classical supercomputers for certain tasks. Thermal sensors hold potential for enhancing such devices because they do not add quantum noise and they are smaller, simpler and consume about six orders of magnitude less power than the frequently used travelling-wave parametric amplifiers. However, despite great progress in the speed and noise levels of thermal sensors, no bolometer has previously met the threshold for circuit quantum electrodynamics, which lies at a time constant of a few hundred nanoseconds and a simultaneous energy resolution of the order of 10h gigahertz (where h is the Planck constant). Here we experimentally demonstrate a bolometer that operates at this threshold, with a noise-equivalent power of 30 zeptowatts per square-root hertz, comparable to the lowest value reported so far, at a thermal time constant two orders of magnitude shorter, at 500 nanoseconds. Both of these values are measured directly on the same device, giving an accurate estimation of 30h gigahertz for the calorimetric energy resolution. These improvements stem from the use of a graphene monolayer with extremely low specific heat as the active material. The minimum observed time constant of 200 nanoseconds is well below the dephasing times of roughly 100 microseconds reported for superconducting qubits and matches the timescales of currently used readout schemes, thus enabling circuit quantum electrodynamics applications for bolometers.
Description
| openaire: EC/H2020/824109/EU//EMP | openaire: EC/H2020/681311/EU//QUESS | openaire: EC/H2020/670743/EU//QuDeT | openaire: EC/H2020/820505/EU//QMiCS
Keywords
Bolometer, microwave, detector, cQED
Other note
Citation
Kokkoniemi, R, Girard, J-P, Hazra, D, Laitinen, A, Govenius, J, Lake, R, Sallinen, I, Vesterinen, V, Partanen, M, Tan, J Y, Chan, K W, Tan, K, Hakonen, P J & Möttönen, M 2020, ' Bolometer operating at the threshold for circuit quantum electrodynamics ', Nature, vol. 586, no. 7827, pp. 47–51 . https://doi.org/10.1038/s41586-020-2753-3