Developing an active heat recovery system to boost data centre waste heat utilization : a novel and cost-effective solution for building decarbonisation
Loading...
Access rights
openAccess
CC BY
CC BY
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Date
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
16
Series
Energy, Volume 341
Abstract
Data centre (DC) waste heat recovery for district-heated buildings often relies on costly heat pumps. However, the rise of liquid-cooled distributed/edge DCs driven by increasing computational demand offers new potential for cost-effective onsite recovery. These systems produce higher-temperature waste heat, making heat exchanger-only solutions more feasible. Yet full recovery remains challenging due to high return water temperatures in building heating networks and the passive nature of such systems. To overcome these limitations, this paper proposes an active DC waste heat recovery system (AHE-DCWHR) that enhances heat exchanger-only solutions through an innovative heating demand reallocation strategy. This strategy utilizes a small heat pump (1) to precool the return water of one heating network before entering the heat exchanger, increasing the inlet temperature difference to enable near-complete waste heat recovery, and (2) to reuse the extracted precooling energy to heat another network, minimizing losses. AHE-DCWHR was validated in TRNSYS through 25-year life-cycle cost (LCC) and emission analyses for a liquid-cooled DC suppling 25 kW of waste heat to a district-heated building. During the 5-month winter, AHE-DCWHR consumed only 7.5 MWh of electricity for the heat pump (average COP = 4.75), enabling the heat exchanger to recover 98.4 % of the waste heat (∼90 MWh), a 16 % improvement over the heat exchanger-only system (75.1 MWh). Based on 25-year LCC and emission analyses, it saves €123,431 heating costs (vs. €106,501 for the heat exchanger-only system), cuts CO2 emissions by 167,087 kg (vs. 134,711 kg), and achieves a two-year payback. AHE-DCWHR cost-effectively outperforms heat exchanger-only and heat pump systems.Description
Publisher Copyright: © 2025 The Authors
Other note
Citation
Lu, T, Lü, X, Clements-Croome, D, Yuan, Y & Martinkauppi, B 2025, 'Developing an active heat recovery system to boost data centre waste heat utilization : a novel and cost-effective solution for building decarbonisation', Energy, vol. 341, 139324. https://doi.org/10.1016/j.energy.2025.139324