Examination of electric arc behavior in open air

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorSingh, Vikramjit
dc.contributor.departmentSähkötekniikan laitosfi
dc.contributor.schoolSähkötekniikan korkeakoulufi
dc.contributor.supervisorLehtonen, Matti
dc.date.accessioned2013-02-11T14:23:53Z
dc.date.available2013-02-11T14:23:53Z
dc.date.issued2012
dc.description.abstractArching faults which endanger the personnel and equipment near to its vicinity must be controlled so that we have high power quality, more security as well as more reliability in power systems. Therefore careful study of electric arc behavior in air is needed, more specifically how different parameters which affect reignition, behave near current zero. A lot of research has been done, finding this behavior near current zero, in order to have better understanding of when interruption is possible, but generally those were concentrated on looking, this behavior, after arc interruption. In this thesis, a different approach has been used to find the arc behavior near current zero. Basically indirect parameters of arc model has been found out, 15 micro seconds before current zero, which tells the conductivity decay at that instant and Mayr Arc Model has been used to find out these parameters. Dependence of breakdown voltage of air, on temperature has also been investigated and different electrode materials have been used in order to see electrode material dependence on breakdown voltage at a specific temperature of gap space.fi
dc.format.extent93 s.
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/7746
dc.identifier.urnURN:NBN:fi:aalto-201302121442
dc.language.isoenen
dc.locationP1fi
dc.programme.majorSähköverkot ja suurjännitetekniikkafi
dc.programme.mcodeS-18
dc.rights.accesslevelopenAccess
dc.subject.keywordarcing faultsen
dc.subject.keywordarc parametersen
dc.subject.keywordbreakdown voltageen
dc.subject.keywordtemperatureen
dc.subject.keywordinterruptionen
dc.subject.keywordreignitionen
dc.subject.keywordcurrent zeroen
dc.titleExamination of electric arc behavior in open airen
dc.typeG2 Pro gradu, diplomityöfi
dc.type.dcmitypetexten
dc.type.okmG2 Pro gradu, diplomityö
dc.type.ontasotDiplomityöfi
dc.type.ontasotMaster's thesisen
dc.type.publicationmasterThesis
local.aalto.digifolderAalto_90901
local.aalto.idinssi45698
local.aalto.openaccessyes