Applications of refrigerant R1234yf in heating, air conditioning and refrigeration systems: A decade of researches

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorGarcia Pabon, Juan Joseen_US
dc.contributor.authorKhosravi, Alien_US
dc.contributor.authorBelman-Flores, J.M.en_US
dc.contributor.authorMachado, Luizen_US
dc.contributor.authorRevellin, Rémien_US
dc.contributor.departmentDepartment of Energy and Mechanical Engineeringen
dc.contributor.groupauthorEnergy efficiency and systemsen
dc.contributor.organizationFederal University of Itajubáen_US
dc.contributor.organizationUniversity of Guanajuatoen_US
dc.contributor.organizationUniversidade Federal de Minas Geraisen_US
dc.contributor.organizationUniversity of Lyonen_US
dc.date.accessioned2020-07-03T11:06:59Z
dc.date.available2020-07-03T11:06:59Z
dc.date.embargoinfo:eu-repo/date/embargoEnd/2022-06-20en_US
dc.date.issued2020-10en_US
dc.description.abstractHFC refrigerants as R134a, R404A, R407C and R410A are commonly used in heating, air conditioning and refrigeration (HACR) systems since Kyoto protocol. However, they are phased-out due to their high global warming potential (GWP). There are various options to replace high GWP refrigerants, among all hydrofluorolefin (HFO) fluids, such as R1234yf, represents an excellent alternative. With GWP <1, R1234yf is a promising substitute for R134a. This paper presents the most relevant researches concerning the application of R1234yf in the last decade. This review paper regroups experimental and theoretical studies which assess the performance of pure R1234yf as working fluid of the compression systems such as mobile and residential air conditioning, air and water heat pump, domestic refrigerator and freezer. Studies depict that R1234yf can be recommended for small-scale systems instead of R134a, but an optimization process is necessary to achieve the optimum operating conditions.en
dc.description.versionPeer revieweden
dc.format.extent10
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationGarcia Pabon, J J, Khosravi, A, Belman-Flores, J M, Machado, L & Revellin, R 2020, 'Applications of refrigerant R1234yf in heating, air conditioning and refrigeration systems: A decade of researches', International Journal of Refrigeration-Revue Internationale du Froid, vol. 118, pp. 104-113. https://doi.org/10.1016/j.ijrefrig.2020.06.014en
dc.identifier.doi10.1016/j.ijrefrig.2020.06.014en_US
dc.identifier.issn0140-7007
dc.identifier.issn1879-2081
dc.identifier.otherPURE UUID: 3c921a5b-2177-4d94-a9f5-b1c0a02ef519en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/3c921a5b-2177-4d94-a9f5-b1c0a02ef519en_US
dc.identifier.otherPURE LINK: http://www.scopus.com/inward/record.url?scp=85089096709&partnerID=8YFLogxK
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/43825647/ENG_Pabon_et_al_Applications_of_refrigerant_R1234yf_International_Journal_of_Refrigeration.pdfen_US
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/45312
dc.identifier.urnURN:NBN:fi:aalto-202007034269
dc.language.isoenen
dc.publisherElsevier
dc.relation.ispartofseriesInternational Journal of Refrigeration-Revue Internationale du Froiden
dc.relation.ispartofseriesVolume 118, pp. 104-113en
dc.rightsopenAccessen
dc.subject.keywordR1234yfen_US
dc.subject.keywordHFOen_US
dc.subject.keywordlow GWP refrigeranten_US
dc.subject.keywordHACR systemsen_US
dc.subject.keywordreview paperen_US
dc.titleApplications of refrigerant R1234yf in heating, air conditioning and refrigeration systems: A decade of researchesen
dc.typeA2 Katsausartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionacceptedVersion

Files