Ecg localization method based on volume conductor model and kalman filtering

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorNakano, Yukien_US
dc.contributor.authorRashed, Essam A.en_US
dc.contributor.authorNakane, Tatsuhitoen_US
dc.contributor.authorLaakso, Ilkkaen_US
dc.contributor.authorHirata, Akimasaen_US
dc.contributor.departmentDepartment of Electrical Engineering and Automationen
dc.contributor.groupauthorElectromagnetics in Health Technologyen
dc.contributor.organizationNagoya Institute of Technologyen_US
dc.date.accessioned2021-07-01T13:08:04Z
dc.date.available2021-07-01T13:08:04Z
dc.date.issued2021-06-22en_US
dc.descriptionFunding Information: This research was conducted by general funding of the Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Japan. Publisher Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
dc.description.abstractThe 12-lead electrocardiogram was invented more than 100 years ago and is still used as an essential tool in the early detection of heart disease. By estimating the time-varying source of the electrical activity from the potential changes, several types of heart disease can be noninvasively identified. However, most previous studies are based on signal processing, and thus an approach that includes physics modeling would be helpful for source localization problems. This study proposes a localization method for cardiac sources by combining an electrical analysis with a volume conductor model of the human body as a forward problem and a sparse reconstruction method as an inverse problem. Our formulation estimates not only the current source location but also the current direction. For a 12-lead electrocardiogram system, a sensitivity analysis of the localization to cardiac volume, tilted angle, and model inhomogeneity was evaluated. Finally, the estimated source location is corrected by Kalman filter, considering the estimated electrocardiogram source as time-sequence data. For a high signal-to-noise ratio (greater than 20 dB), the dominant error sources were the model inhomogeneity, which is mainly attributable to the high conductivity of the blood in the heart. The average localization error of the electric dipole sources in the heart was 12.6 mm, which is comparable to that in previous studies, where a less detailed anatomical structure was considered. A time-series source localization with Kalman filtering indicated that source mislocalization could be compensated, suggesting the effectiveness of the source estimation using the current direction and location simultaneously. For the electrocardiogram R-wave, the mean distance error was reduced to less than 7.3 mm using the proposed method. Considering the physical properties of the human body with Kalman filtering enables highly accurate estimation of the cardiac electric signal source location and direction. This proposal is also applicable to electrode configuration, such as ECG sensing systems.en
dc.description.versionPeer revieweden
dc.format.extent18
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationNakano, Y, Rashed, E A, Nakane, T, Laakso, I & Hirata, A 2021, 'Ecg localization method based on volume conductor model and kalman filtering', Sensors, vol. 21, no. 13, 4275. https://doi.org/10.3390/s21134275en
dc.identifier.doi10.3390/s21134275en_US
dc.identifier.issn1424-8220
dc.identifier.otherPURE UUID: 9b1fe39d-342f-471c-b9ee-ad16eb243f59en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/9b1fe39d-342f-471c-b9ee-ad16eb243f59en_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/65309995/ELEC_Nakano_etal_ECG_Localization_Method_Based_Sensors_2021_finalpublishedversion.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/108624
dc.identifier.urnURN:NBN:fi:aalto-202107017878
dc.language.isoenen
dc.publisherMDPI AG
dc.relation.fundinginfoThis research was conducted by general funding of the Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Japan.
dc.relation.ispartofseriesSensorsen
dc.relation.ispartofseriesVolume 21, issue 13en
dc.rightsopenAccessen
dc.subject.keywordCardiac source localizationen_US
dc.subject.keywordElectrocardiographyen_US
dc.subject.keywordFinite difference methodsen_US
dc.subject.keywordInverse problemsen_US
dc.titleEcg localization method based on volume conductor model and kalman filteringen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files