aalto1 untyped-item.component.html
Ecg localization method based on volume conductor model and kalman filtering
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Date
Major/Subject
Mcode
Degree programme
Language
en
Pages
18
Series
Sensors, Volume 21, issue 13
Abstract
The 12-lead electrocardiogram was invented more than 100 years ago and is still used as an essential tool in the early detection of heart disease. By estimating the time-varying source of the electrical activity from the potential changes, several types of heart disease can be noninvasively identified. However, most previous studies are based on signal processing, and thus an approach that includes physics modeling would be helpful for source localization problems. This study proposes a localization method for cardiac sources by combining an electrical analysis with a volume conductor model of the human body as a forward problem and a sparse reconstruction method as an inverse problem. Our formulation estimates not only the current source location but also the current direction. For a 12-lead electrocardiogram system, a sensitivity analysis of the localization to cardiac volume, tilted angle, and model inhomogeneity was evaluated. Finally, the estimated source location is corrected by Kalman filter, considering the estimated electrocardiogram source as time-sequence data. For a high signal-to-noise ratio (greater than 20 dB), the dominant error sources were the model inhomogeneity, which is mainly attributable to the high conductivity of the blood in the heart. The average localization error of the electric dipole sources in the heart was 12.6 mm, which is comparable to that in previous studies, where a less detailed anatomical structure was considered. A time-series source localization with Kalman filtering indicated that source mislocalization could be compensated, suggesting the effectiveness of the source estimation using the current direction and location simultaneously. For the electrocardiogram R-wave, the mean distance error was reduced to less than 7.3 mm using the proposed method. Considering the physical properties of the human body with Kalman filtering enables highly accurate estimation of the cardiac electric signal source location and direction. This proposal is also applicable to electrode configuration, such as ECG sensing systems.
Description
Funding Information: This research was conducted by general funding of the Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Japan. Publisher Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Other note
Citation
Nakano, Y, Rashed, E A, Nakane, T, Laakso, I & Hirata, A 2021, 'Ecg localization method based on volume conductor model and kalman filtering', Sensors, vol. 21, no. 13, 4275. https://doi.org/10.3390/s21134275