Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorSaikko, Vesa
dc.contributor.authorVuorinen, Vesa
dc.contributor.authorRevitzer, Hannu
dc.contributor.departmentKonetekniikan laitosfi
dc.contributor.departmentDepartment of Mechanical Engineeringen
dc.contributor.departmentKemian laitosfi
dc.contributor.departmentDepartment of Chemistryen
dc.contributor.departmentSähkötekniikan ja automaation laitosfi
dc.contributor.departmentDepartment of Electrical Engineering and Automationen
dc.contributor.schoolInsinööritieteiden korkeakoulufi
dc.contributor.schoolSchool of Engineeringen
dc.contributor.schoolKemian tekniikan korkeakoulufi
dc.contributor.schoolSchool of Chemical Technologyen
dc.contributor.schoolSähkötekniikan korkeakoulufi
dc.contributor.schoolSchool of Electrical Engineeringen
dc.date.accessioned2016-04-29T09:01:25Z
dc.date.available2016-04-29T09:01:25Z
dc.date.issued2015
dc.description.versionPeer revieweden
dc.format.extent30-34
dc.format.mimetypeapplication/pdfen
dc.identifier.citationSaikko, Vesa & Vuorinen, Vesa & Revitzer, Hannu. 2015. Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system. Biotribology. Volumes 1-2. 30-34. ISSN 2352-5738 (electronic). DOI: 10.1016/j.biotri.2015.03.002.en
dc.identifier.doi10.1016/j.biotri.2015.03.002
dc.identifier.issn2352-5738 (electronic)
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/20239
dc.identifier.urnURN:NBN:fi:aalto-201604281888
dc.language.isoenen
dc.publisherElsevieren
dc.relation.ispartofseriesBiotribologyen
dc.relation.ispartofseriesVolumes 1-2
dc.rights© 2015 Elsevier. This is the post print version of the following article: Saikko, Vesa & Vuorinen, Vesa & Revitzer, Hannu. 2015. Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system. Biotribology. Volumes 1-2. 30-34. ISSN 2352-5738 (electronic). DOI: 10.1016/j.biotri.2015.03.002, which has been published in final form at http://www.sciencedirect.com/science/article/pii/S2352573815000050.en
dc.rights.holderElsevier
dc.subject.keywordnon-cyclicen
dc.subject.keywordrandomnessen
dc.subject.keywordwear simulationen
dc.subject.keywordwear mechanismen
dc.subject.keywordUHMWPEen
dc.subject.otherChemistryen
dc.subject.otherElectrical engineeringen
dc.subject.otherMechanical engineeringen
dc.titleAnalysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD systemen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.dcmitypetexten
dc.type.versionPost printen
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
A1_saikko_vesa_2015.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format