Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system
dc.contributor | Aalto-yliopisto | fi |
dc.contributor | Aalto University | en |
dc.contributor.author | Saikko, Vesa | |
dc.contributor.author | Vuorinen, Vesa | |
dc.contributor.author | Revitzer, Hannu | |
dc.contributor.department | Konetekniikan laitos | fi |
dc.contributor.department | Department of Mechanical Engineering | en |
dc.contributor.department | Kemian laitos | fi |
dc.contributor.department | Department of Chemistry | en |
dc.contributor.department | Sähkötekniikan ja automaation laitos | fi |
dc.contributor.department | Department of Electrical Engineering and Automation | en |
dc.contributor.school | Insinööritieteiden korkeakoulu | fi |
dc.contributor.school | School of Engineering | en |
dc.contributor.school | Kemian tekniikan korkeakoulu | fi |
dc.contributor.school | School of Chemical Technology | en |
dc.contributor.school | Sähkötekniikan korkeakoulu | fi |
dc.contributor.school | School of Electrical Engineering | en |
dc.date.accessioned | 2016-04-29T09:01:25Z | |
dc.date.available | 2016-04-29T09:01:25Z | |
dc.date.issued | 2015 | |
dc.description.version | Peer reviewed | en |
dc.format.extent | 30-34 | |
dc.format.mimetype | application/pdf | en |
dc.identifier.citation | Saikko, Vesa & Vuorinen, Vesa & Revitzer, Hannu. 2015. Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system. Biotribology. Volumes 1-2. 30-34. ISSN 2352-5738 (electronic). DOI: 10.1016/j.biotri.2015.03.002. | en |
dc.identifier.doi | 10.1016/j.biotri.2015.03.002 | |
dc.identifier.issn | 2352-5738 (electronic) | |
dc.identifier.uri | https://aaltodoc.aalto.fi/handle/123456789/20239 | |
dc.identifier.urn | URN:NBN:fi:aalto-201604281888 | |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.relation.ispartofseries | Biotribology | en |
dc.relation.ispartofseries | Volumes 1-2 | |
dc.rights | © 2015 Elsevier. This is the post print version of the following article: Saikko, Vesa & Vuorinen, Vesa & Revitzer, Hannu. 2015. Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system. Biotribology. Volumes 1-2. 30-34. ISSN 2352-5738 (electronic). DOI: 10.1016/j.biotri.2015.03.002, which has been published in final form at http://www.sciencedirect.com/science/article/pii/S2352573815000050. | en |
dc.rights.holder | Elsevier | |
dc.subject.keyword | non-cyclic | en |
dc.subject.keyword | randomness | en |
dc.subject.keyword | wear simulation | en |
dc.subject.keyword | wear mechanism | en |
dc.subject.keyword | UHMWPE | en |
dc.subject.other | Chemistry | en |
dc.subject.other | Electrical engineering | en |
dc.subject.other | Mechanical engineering | en |
dc.title | Analysis of UHMWPE wear particles produced in the simulation of hip and knee wear mechanisms with the RandomPOD system | en |
dc.type | A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä | fi |
dc.type.dcmitype | text | en |
dc.type.version | Post print | en |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- A1_saikko_vesa_2015.pdf
- Size:
- 1.87 MB
- Format:
- Adobe Portable Document Format