Energy performance, indoor air quality and comfort in new nearly zero energy day-care centres in northern climatic conditions
Loading...
Access rights
openAccess
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
Date
2019-04-17
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
10
7-16
7-16
Series
Journal of Sustainable Architecture and Civil Engineering, Volume 24, issue 1
Abstract
The European energy policy pushes the member states to transform building stock into nearly Zero-Energy Buildings (nZEB). This paper is focused on data collected from existing nZEB day-care centres, in order to be able to assess possible differences between predicted and actual energy and indoor environmental performance. Building structures, service systems and the indoor climate and energy performance of five day-care centres were investigated in Estonia, Finland and Norway. Indoor climate condition measurements showed that in general, the thermal environment and indoor air quality corresponded to the highest indoor climate categories I and II (EN 15251). Building heating and ventilation systems in studied buildings are working without major problems. Good indoor climate conditions were also reflected in the occupant satisfaction questionnaires. For most of the studied buildings, over 80% of the people marked all indoor environment condition parameters (thermal comfort, indoor air quality, acoustics, odour and illuminance) acceptable. The thermal environment in the cooling season was reported problematic because it was lower than the minimum temperature for indoor climate category II. Energy consumption analysis showed that measured real energy use was higher, or even significantly higher, than the energy use calculated during the design phase. Potential causes of the higher actual energy consumption are caused by differences of measured and designed solutions, methodology of the energy calculations, and the differences in user behaviour. Lessons learnt from previously constructed day-care centres can be utilised in the planning and design of new nZEBs.Description
Keywords
Day-care centres, Energy consumption, Indoor air quality, Indoor thermal conditions, nZEB, Occupant satisfaction
Other note
Citation
Kuusk, K, Ahmed, K, Lolli, N, Johansson, J, Hasu, T, Lien, A G, Arumägi, E, Kalbe, K, Hallik, J, Kurnitski, J & Kalamees, T 2019, ' Energy performance, indoor air quality and comfort in new nearly zero energy day-care centres in northern climatic conditions ', Journal of Sustainable Architecture and Civil Engineering, vol. 24, no. 1, pp. 7-16 . https://doi.org/10.5755/j01.sace.24.1.22180