Urea injection in power plants to reduce NOx emission

No Thumbnail Available

URL

Journal Title

Journal ISSN

Volume Title

School of Chemical Engineering | Master's thesis
Checking the digitized thesis and permission for publishing
Instructions for the author

Date

2012

Department

Major/Subject

Tehdassuunnittelu

Mcode

Kem-107

Degree programme

Language

en

Pages

xi + 104 + [3]

Series

Abstract

The EU Directive 2010/75/EU, Industrial Emissions Directive (IED), limited the NOx emission level < 200 mg/m<sup>3</sup>n at 6% O<sub>2</sub> content from combustion plants into the air at 2016. For achieving NOx emission limitation, Fortum is developing a new combustion technology which includes new third generation Low-NOx burners and advanced OFA system combining with rich reagent injection (RRI) in to the boiler. The aim of the thesis was to study NOx reduction capability of RRI and the effect of reagent on the combustion system at PC firing Power Plants. Two experiments were performed at Inkoo and Suomenoja Power Plants, in which Inkoo has a single wall firing boiler and Suomenoja has tangentially firing boiler. During the test runs, the urea concentration was 32.5 wt. % and three types' urea spray nozzles were prepared to both Power Plants. Coal samples and fly ash samples were collected and analysed in laboratory to determine the coal quality and UBC content and ammonia content in fly ash. Gypsum samples and waste water samples were collected after FGD unit and analysed in laboratory in order to examine the ammonia content. NOx emission was measured by NOx-analyser before the flue gas fan and FTIR was used to measure the gases concentration after the flue gas fan. According to RRI test results, the NOx reduction was achieved 52 mg/m<sup>3</sup>n (13.5%) at Inkoo and 98 mg/m<sup>3</sup>n (21%) at Suomenoja with using C-type urea nozzle. The results indicated that urea injection had no remarkable effect on increasing N<sub>2</sub>O emission, CO emission and UBC content in fly ash. No ammonia slip was found in fly ash and FGD unit. Urea injection had no negative effect on increasing water spray amount to superheater or reheater and steam temperature. In addition, the tendency of NOx reduction was same for the CFD calculation and tests at Power Plants. Based on the tests results and CFD modelling, optimizing existed combustion systems combined with RRI would achieve NOx emission < 200 mg/m<sup>3</sup>.

Description

Supervisor

Koskinen, Jukka

Thesis advisor

Savolainen, Kati

Keywords

NOx emission, RRI, low-NOx burners, OFA

Other note

Citation