Revisiting Stewart–Gough platform applications: A kinematic pavilion
Loading...
Access rights
openAccess
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Date
2021-12-15
Major/Subject
Mcode
Degree programme
Language
en
Pages
18
Series
Engineering Structures, Volume 249
Abstract
Stewart–Gough platforms are well known for their extraordinary kinematic motion and therefore they are widely used as devices, ranging from flight simulators to microsurgical manipulators. However, they have not yet been explored much as architectural objects and transformable spaces with regards to irregular arrangements of legs and their associate structural performance. In the current study, an innovative architectural and structural application of the Stewart–Gough platform, implemented as full-scale kinematic pavilion, namely the Zero Gravity pavilion, at Aalto University, Finland, is presented. During the design process a Stewart–Gough 3–3 configuration was rearranged to an irregular 6–6 configuration. The architectural freedom in the arrangement of columns was guided by its immanent effect on the structure’s motion, stability, and strength. We opted for one telescopic leg only and its selection is based on four main criteria. Firstly, for each telescopic leg the stability of the different configurations is investigated. Secondly, the self-collision of leg–leg, leg–roof, and roof–floor was investigated by means of physical and computational models as well as through the full-scale pavilion. Thirdly, the selection process is influenced by the force distribution on the six legs. Fourthly, the path trajectory of the kinematic structure is examined in terms of magnitude and type of motion as an architectural feature. The final choice of the telescopic leg was based on the conclusions drawn from the parametric architectural and structural studies. The overall spatial and structural qualities of the system was validated by the full-scale Zero Gravity pavilion.Description
Keywords
Stewart–Gough platform, Transformable architecture, Structural design, Stability, Kinematic structure
Other note
Citation
Markou, A, Elmas, S & Filz, G H 2021, ' Revisiting Stewart–Gough platform applications: A kinematic pavilion ', Engineering Structures, vol. 249, 113304 . https://doi.org/10.1016/j.engstruct.2021.113304