Fracture of warm S2 columnar freshwater ice: size and rate effects
Loading...
Access rights
openAccess
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
Date
2021-01-01
Major/Subject
Mcode
Degree programme
Language
en
Pages
13
22-34
22-34
Series
Acta Materialia, Volume 202
Abstract
Large scale laboratory experiments on size and rate effects on the fracture of warm columnar freshwater ice have been conducted with floating edge-cracked rectangular plates loaded at the crack mouth. The largest test plate size had dimensions of 19.5m x 36m. The overall crack-parallel dimension covered a size range of 1 : 39 , possibly the largest for ice tested under laboratory conditions. The loading rates applied led to test durations from fewer than 2 seconds to more than 1000 seconds, leading to an elastic response at the highest rates to a viscoelastic response at the lower rates. Methods for both the linear elastic fracture mechanics (LEFM) and a non-linear viscoelastic fictitious crack model (VFCM) were derived to analyze the data and calculate values for the apparent fracture toughness, crack opening displacement, stress-separation curve, fracture energy, and size of the process zone near a crack tip. Issues of notch sensitivity and minimum size requirements for polycrystalline homogeneity were addressed. Both size and rate effects were observed, as well as how these two factors are interrelated in the fracture of columnar freshwater ice. There was a size effect at low rates but no size effect at high rates. There was a rate effect for the larger test sizes but a weaker or no rate effect for the smallest test size. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )Description
Keywords
fracture, Freshwater S2 ice, rate effect, size effect, viscoelasticity
Other note
Citation
Gharamti, I E, Dempsey, J P, Polojärvi, A & Tuhkuri, J 2021, ' Fracture of warm S2 columnar freshwater ice : size and rate effects ', Acta Materialia, vol. 202, pp. 22-34 . https://doi.org/10.1016/j.actamat.2020.10.031