Measurement of bidirectional transmittance distribution function in the visible and near-infrared spectral range
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Other link related to publication (opens in new window)
Date
2024-10-01
Major/Subject
Mcode
Degree programme
Language
en
Pages
16
Series
Metrologia, Volume 61, issue 5
Abstract
This work characterizes a facility for bidirectional transmittance distribution function (BTDF) measurements in the visible and near-infrared (NIR) wavelength range. The facility includes an absolute reference gonioreflectometer, with an extended capability for BTDF measurements, and a commercial instrument, Cary 7000, using a goniometer extension, Universal Measurement Accessory. The facility characterization includes measurements of two quasi-Lambertian diffusers for their BTDF. The diffuser samples include a piece of porous polytetrafluoroethylene (PTFE) and a piece of fused synthetic silica, HOD-500. The samples are measured for their spectral BTDF in the wavelength range from 450 nm to 1650 nm in 50 nm steps, and in the viewing zenith angle range from −35° to 35° in 5° steps. Measurements are performed in-plane, using an incident zenith angle of 0°, while rotating the samples around their surface normal from 0° to 180° in 90° steps. Rotation of the sample serves the dual purpose of checking the sample rotational symmetry in azimuth angles and for averaging the measurement results. The characterization results show that both samples exhibit Lambertian characteristics across the visible and NIR wavelength range. Furthermore, both samples show a smooth increase in their spectral BTDF as a function of wavelength. Notably, the PTFE sample demonstrates a steeper slope in its spectral BTDF and a higher signal above 650 nm. The facility capability for measurements of spectral BTDF is validated by a rigorous uncertainty analysis and by comparing the difference in measurement results between the absolute gonioreflectometer and the commercial instrument. Characterization results indicate that the absolute reference gonioreflectometer has a standard uncertainty ranging from 0.29% to 0.42%, dependent on the BTDF measurement wavelength. Experimental results show that the devices of the facility deviate in their BTDF within their combined expanded uncertainty, affirming the capability and reliability of the facility for BTDF measurements.Description
Publisher Copyright: © 2024 The Author(s). Published on behalf of BIPM by IOP Publishing Ltd.
Keywords
cary 7000, gonioreflectometer, HOD-500, near-infrared, PTFE, spectral BTDF, uncertainty characterization
Other note
Citation
Aschan, R, Manoocheri, F, Lanevski, D & Ikonen, E 2024, ' Measurement of bidirectional transmittance distribution function in the visible and near-infrared spectral range ', Metrologia, vol. 61, no. 5, 055004 . https://doi.org/10.1088/1681-7575/ad60ca