Passiivisen keräimen käyttö lattiarakenteiden kemiallisten päästöjen määrittämisessä

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.advisorWirtanen, Leif
dc.contributor.advisorRonkainen, Mika
dc.contributor.authorLiljendahl, Joona
dc.contributor.schoolInsinööritieteiden korkeakoulufi
dc.contributor.supervisorSalonen, Heidi
dc.date.accessioned2023-12-18T20:06:08Z
dc.date.available2023-12-18T20:06:08Z
dc.date.issued2023-12-11
dc.description.abstractLiian kostean betonilattian päälle asennettu matto voi alkaa kemiallisesti hajoamaan betonin alkalisen kosteuden vaikutuksesta. Maton hajoaminen ilmenee usein kohonneina VOC-emissioina. Tällä hetkellä mattojen VOC-emissioita mitataan usein laboratorioon vietävällä näytepalalla tai paikallisesti FLEC-menetelmällä, mutta molemmat näistä menetelmistä ovat monimutkaisia ja kalliita. Tässä työssä tutkittiin kuvun alle asetettua passiivikeräintä ja pohdittiin sen käyttömahdollisuuksia lattiamateriaalien VOC-emissioiden mittaamiseen. Tuloksia verrattiin FLEC-menetelmällä saatuihin tuloksiin. Passiivikeräimeksi valittiin Radiello-keräin, jonka etuna on sen muotoilu, saatavuus sekä hinta. Koekappaleet olivat betonilaattoja, joiden päälle liimattiin PVC- sekä linoleumimattoja. Kappaleiden päältä mitattiin VOC-yhdisteitä molemmilla menetelmillä. Tulokset osoittivat, että passiivikeräinkammio voi olla yksinkertaisempi sekä edullisempi vaihtoehto FLEC-menetelmälle, mutta ei välttämättä yhtä tarkka. Eri menetelmillä saadut tulokset erosivat toisistaan joissain tapauksissa paljonkin. Osa tulosten eroista voidaan selittää erilaisten adsorbenttien käytöllä sekä mittauksien monilla virhelähteillä, mutta passiivisen ja aktiivisen menetelmän erilaisten toimintatapojen vuoksi niillä on hankala saada suoraan verrattavissa olevia tuloksia. Molemmilla menetelmillä tosin tunnistettiin vastaavia muutoksia yhdisteiden pitoisuuksissa itsenäisesti. Passiivikeräinkammion tulokset verrattuna toisiinsa vaikuttivat johdonmukaisilta ja niistä voidaan päätellä, että menetelmä voi sopia materiaalien VOC-emissioiden tunnistamiseen sekä vertailuun. Pienen koon sekä helppokäyttöisyyden vuoksi menetelmä sopisi myös laajoihin kohdetutkimuksiin. Passiivikeräinmenetelmä tosin vaatii vielä lisätutkimuksia ainakin sopivan näytteenottoajan sekä tulosten käsittelyn osalta.fi
dc.description.abstractFloor coverings may start to degrade due to being glued to a concrete floor that has a high relative humidity and pH. This degradation often results in unusually high VOC-emissions. The VOC-emissions can be measured by delivering a sample to a laboratory or on-site with the FLEC-method. However, both of these methods are complicated and expensive. This paper evaluates the use of passive samplers that are placed under a bowl to measure VOC-emissions from floorings. The results were compared to the FLEC-method. Radiello passive sampler was chosen due to it’s good geometry, availability and price. The test samples were PVC and linoleum floorings glued to a concrete slab to simulate a floor structure. The emission of these test samples were then measured with both methods. The results indicated that the passive emission chamber could be an easier and cheaper substitute for the FLEC-method, but maybe not as accurate. The results with the different methods varied with eachother considerably in some cases. Some of these variations could be explained with the use of different adsorbents and with the many sources of errors, but since the methods have so different operating principles, it is hard to get comparable results. Although, similar trends in the VOC concentrations could still be observed with both methods. The results obtained with the passive emission chamber seemed consistent which indicated that the passive method could be used to identify and compare VOC-emissions. The small size and easy operation of the passive chamber makes it suitable even for large on-site studies. However, the passive chamber method still requires further studies to determine the right exposure time and the processing of the results.en
dc.format.extent54 + 18
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/125010
dc.identifier.urnURN:NBN:fi:aalto-202312187378
dc.language.isofien
dc.programmeMaster's Programme in Building Technology (CIV)fi
dc.subject.keywordpassiivikeräinfi
dc.subject.keywordemissiokammiofi
dc.subject.keywordmateriaaliemissiofi
dc.subject.keywordRadiellofi
dc.subject.keywordFLECfi
dc.titlePassiivisen keräimen käyttö lattiarakenteiden kemiallisten päästöjen määrittämisessäfi
dc.titleDetermining floor structure emissions with a passive sampleren
dc.typeG2 Pro gradu, diplomityöfi
dc.type.ontasotMaster's thesisen
dc.type.ontasotDiplomityöfi
local.aalto.electroniconlyyes
local.aalto.openaccessyes