aalto1 untyped-item.component.html

Observer-based state-space current control for a three-phase grid-connected converter equipped with an LCL filter

Loading...
Thumbnail Image

Access rights

openAccess
acceptedVersion

URL

Journal Title

Journal ISSN

Volume Title

A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Major/Subject

Mcode

Degree programme

Language

en

Pages

Series

IEEE Transactions on Industry Applications, Volume 50, issue 4, pp. 2700-2709

Abstract

This paper presents a state-space current control method for active damping of the resonance frequency of the LCL filter and setting the dominant dynamics of the converter current through direct pole placement. A state observer is used, where upon additional sensors are not needed in comparison with the conventional L filter design. The relationship between the system delay and instability caused by the resonance phenomenon is considered. Nyquist diagrams are used to examine the parameter sensitivity of the proposed method. The method is validated with simulations and experiments.

Description

Other note

Citation

Kukkola, J & Hinkkanen, M 2014, 'Observer-based state-space current control for a three-phase grid-connected converter equipped with an LCL filter', IEEE Transactions on Industry Applications, vol. 50, no. 4, pp. 2700-2709. https://doi.org/10.1109/TIA.2013.2295461

Endorsement

Review

Supplemented By

Referenced By