aalto1 untyped-item.component.html
Water recovery from flue gas condensate in municipal solid waste fired cogeneration plants using membrane distillation
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Authors
Date
Major/Subject
Mcode
Degree programme
Language
en
Pages
14
Series
Chemical Engineering Journal, Volume 399
Abstract
In cogeneration plants with wet scrubbing of exhaust gases, the resulting flue gas condensate passes through various treatment steps prior to its discharge to recipient water body or for use as boiler feed water. The present investigation examines membrane distillation (MD) as an alternative treatment method, potentially overcoming bio-fouling and other known drawbacks of established membrane technologies while making efficient use of available heat sources and sinks. Laboratory and pilot scale experiments are performed using air gap MD system where acid neutralization has been considered as a pretreatment step in order to avoid ammonia slip. Separation efficiency, transmembrane flux, specific heat demand and net heat demand were determined at different operating conditions. Resultant separation efficiency of the contaminants shows the successful application of MD for flue gas condensate treatment, achieving results that are comparable or even better than separation with reverse osmosis (RO). The obtained transmembrane flux varied between 1.6 and 7.2 L/m2h per module depending upon the hot and cold side temperatures. For various operating conditions, specific heat demand ranged from 400 to 1000 kWh/m3 per module and corresponding net heat demand was around 17.5–110 kWh/m3. The reconcentration study found that 92% of water could be recovered from the tested flue gas condensate. Process economy shows that estimated clean condensate production cost can be as low as 1.7 $/m3.
Description
Other note
Citation
Noor, I E, Martin, A & Dahl, O 2020, 'Water recovery from flue gas condensate in municipal solid waste fired cogeneration plants using membrane distillation', Chemical Engineering Journal, vol. 399, 125707. https://doi.org/10.1016/j.cej.2020.125707