Planck 2013 results: IX. HFI spectral response
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Date
2014-11
Department
Major/Subject
Mcode
Degree programme
Language
en
Pages
27
Series
Astronomy and Astrophysics, Volume 571
Abstract
The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (including the level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10(8). The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. These coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.Description
Keywords
instrumentation: detectors, instrumentation: photometers, space vehicles: instruments, cosmology: observations, cosmic background radiation, HIGH-FREQUENCY INSTRUMENT, COBE FIRAS INSTRUMENT, MOLECULAR CLOUDS, MICROWAVE, SPECTROSCOPY, CALIBRATION
Other note
Citation
Ade, P A R, Aghanim, N, Armitage-Caplan, C, Arnaud, M, Ashdown, M, Atrio-Barandela, F, Aumont, J, Baccigalupi, C, Banday, A J, Barreiro, R B, Battaner, E, Benabed, K, Benoit, A, Benoit-Levy, A, Bernard, J -P, Bersanelli, M, Bielewicz, P, Bobin, J, Bock, J J, Bond, J R, Borrill, J, Bouchet, F R, Boulanger, F, Bridges, M, Bucher, M, Burigana, C, Cardoso, J -F, Catalano, A, Challinor, A, Chamballu, A, Chary, R -R, Chen, X, Chiang, H C, Chiang, L -Y, Christensen, P R, Church, S, Clements, D L, Colombi, S, Colombo, L P L, Combet, C, Comis, B, Couchot, F, Coulais, A, Crill, B P, Curto, A, Cuttaia, F, Danese, L, Davies, R D, de Bernardis, P, de Rosa, A & Planck Collaboration 2014, ' Planck 2013 results : IX. HFI spectral response ', Astronomy and Astrophysics, vol. 571, A9 . https://doi.org/10.1051/0004-6361/201321531