aalto1 untyped-item.component.html
Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs
Loading...
Access rights
openAccess
publishedVersion
URL
Journal Title
Journal ISSN
Volume Title
A4 Artikkeli konferenssijulkaisussa
This publication is imported from Aalto University research portal.
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
View publication in the Research portal (opens in new window)
View/Open full text file from the Research portal (opens in new window)
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Date
Major/Subject
Mcode
Degree programme
Language
en
Pages
9
Series
Proceedings of the 29th International Workshop on Vertex Detectors, VERTEX 2020, JPS Conference Proceedings ; Volume 34
Abstract
To cope up with high pile-up rates during Phase-2 operation of the LHC, the CMS experiment will install a precision Minimum Ionising Particle Timing Detector (MTD), between the tracker and calorimeter, which will have a timing resolution of ∼30 ps. The endcap part of the MTD, called the Endcap Timing Layer (ETL), will be based on Low-Gain Avalanche Detector (LGAD) Technology. In this paper, the authors have performed a study on UFSD3.1 LGAD production from Fondazione Bruno Kessler (FBK). The objective of this production was to optimise the interplay between the p-stop dose and the inter-pad terminal strategy. Results show that the nominal no-gain region width value between pads does not affect the breakdown voltage of the sensors at low p-stop doses. A comparative study on the effect of thermal donors induced in the bulk of the sensor was performed by capacitance versus voltage measurements. Further, the property of the sensors were investigated using infra-red (IR) laser, by performing voltage scans and inter-pad profile measurements with gain variation, on changing temperature in Transient Current Technique (TCT). Results show no significant change in the charge collection efficiency and measured no-gain region width values of sensors irrespective of the nature of the bulk.
Description
Keywords
Other note
Citation
Bharthuar, S, Ott, J, Brücken, E, Gädda, A, Kirschenmann, S, Golovleva, M & Luukka, P 2021, Effect of Thermal Donors Induced in Bulk and Variation in P-stop Dose on the No-gain Region Width Measurements of LGADs. in Proceedings of the 29th International Workshop on Vertex Detectors, VERTEX 2020. JPS Conference Proceedings, vol. 34, Physical Society of Japan, Tokyo, International Workshop on Vertex Detectors, Tsukuba, Japan, 05/10/2020. https://doi.org/10.7566/JPSCP.34.010020