Evaluation of a Doppler radar sensor system for vital signs detection and activity monitoring in a radio-frequency shielded room

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorKuutti, Jussi
dc.contributor.authorPaukkunen, Mikko
dc.contributor.authorAalto, Miro
dc.contributor.authorEskelinen, Pekka
dc.contributor.authorSepponen, Raimo E.
dc.contributor.departmentDepartment of Electrical Engineering and Automationen
dc.date.accessioned2017-05-11T09:07:10Z
dc.date.available2017-05-11T09:07:10Z
dc.date.issued2015
dc.description.abstractThis study presents an evaluation of an advanced Doppler radar-based method for detection of vital signs, presence, and activity of a human subject in a test room with radar-signal reflecting aluminum-coated surfaces. Ten test subjects lay in four positions, and they sat in two locations in the room, both breathing normally and holding their breath. The mean ratios of the pulse rates determined from the radar signal and electrocardiography and respiration reference signals were 110% (respiration) and 99% (heartbeat), and the mean occupied and empty room radar signal variance ratios were 608 (breathing) and 20 (breath-hold). In a one-subject activity monitoring test, walking, standing and lying activities could be well separated from the radar signal. The results are promising and the proposed system seems to have potential to be used in position-independent health and activity monitoring of, for example, elderly people in care homes or intoxicated people in police custody.en
dc.description.versionPeer revieweden
dc.format.extent135-142
dc.format.mimetypeapplication/pdf
dc.identifier.citationKuutti , J , Paukkunen , M , Aalto , M , Eskelinen , P & Sepponen , R E 2015 , ' Evaluation of a Doppler radar sensor system for vital signs detection and activity monitoring in a radio-frequency shielded room ' , Measurement , vol. 68 , pp. 135-142 . https://doi.org/10.1016/j.measurement.2015.02.048en
dc.identifier.doi10.1016/j.measurement.2015.02.048
dc.identifier.issn0263-2241
dc.identifier.otherPURE UUID: c87111f0-e03d-4b08-b21a-d2dfac288765
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/c87111f0-e03d-4b08-b21a-d2dfac288765
dc.identifier.otherPURE LINK: http://dx.doi.org/10.1016/j.measurement.2015.02.048
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/11693773/1_s2.0_S0263224115001062_main.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/25850
dc.identifier.urnURN:NBN:fi:aalto-201705114225
dc.language.isoenen
dc.relation.ispartofseriesMEASUREMENTen
dc.relation.ispartofseriesVolume 68en
dc.rightsopenAccessen
dc.subject.keywordcell death prevention
dc.subject.keywordcontactless activity monitoring
dc.subject.keywordcontactless vital signs monitoring
dc.subject.keywordDoppler radar sensor
dc.subject.keywordelderly care
dc.titleEvaluation of a Doppler radar sensor system for vital signs detection and activity monitoring in a radio-frequency shielded roomen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files