Software-based planning of ultrasound and CT-guided percutaneous radiofrequency ablation in hepatic tumors

dc.contributorAalto-yliopistofi
dc.contributorAalto Universityen
dc.contributor.authorvan Amerongen, M. J.en_US
dc.contributor.authorMariappan, P.en_US
dc.contributor.authorVoglreiter, P.en_US
dc.contributor.authorFlanagan, R.en_US
dc.contributor.authorJenniskens, S. F.M.en_US
dc.contributor.authorPollari, Mikaen_US
dc.contributor.authorKolesnik, M.en_US
dc.contributor.authorMoche, M.en_US
dc.contributor.authorFütterer, J. J.en_US
dc.contributor.departmentDepartment of Computer Scienceen
dc.contributor.organizationRadboud University Nijmegenen_US
dc.contributor.organizationNUMA Engineering Services Ltden_US
dc.contributor.organizationGraz University of Technologyen_US
dc.contributor.organizationFraunhofer Institute for Applied Information Technologyen_US
dc.contributor.organizationHelios Park-Klinikum Leipzigen_US
dc.contributor.organizationUniversity of Twenteen_US
dc.date.accessioned2021-06-02T06:16:31Z
dc.date.available2021-06-02T06:16:31Z
dc.date.issued2021-06en_US
dc.descriptionPublisher Copyright: © 2021, The Author(s). Copyright: Copyright 2021 Elsevier B.V., All rights reserved.
dc.description.abstractObjectives: Radiofrequency ablation (RFA) can be associated with local recurrences in the treatment of liver tumors. Data obtained at our center for an earlier multinational multicenter trial regarding an in-house developed simulation software were re-evaluated in order to analyze whether the software was able to predict local recurrences. Methods: Twenty-seven RFA ablations for either primary or secondary hepatic tumors were included. Colorectal liver metastases were shown in 14 patients and hepatocellular carcinoma in 13 patients. Overlap of the simulated volume and the tumor volume was automatically generated and defined as positive predictive value (PPV) and additionally visually assessed. Local recurrence during follow-up was defined as gold standard. Sensitivity and specificity were calculated using the visual assessment and gold standard. Results: Mean tumor size was 18 mm (95% CI 15–21 mm). Local recurrence occurred in 5 patients. The PPV of the simulation showed a mean of 0.89 (0.84–0.93 95% CI). After visual assessment, 9 incomplete ablations were observed, of which 4 true positives and 5 false positives for the detection of an incomplete ablation. The sensitivity and specificity were, respectively, 80% and 77% with a correct prediction in 78% of cases. No significant correlation was found between size of the tumor and PPV (Pearson Correlation 0.10; p = 0.62) or between PPV and recurrence rates (Pearson Correlation 0.28; p = 0.16). Conclusions: The simulation software shows promise in estimating the completeness of liver RFA treatment and predicting local recurrence rates, but could not be performed real-time. Future improvements in the field of registration could improve results and provide a possibility for real-time implementation.en
dc.description.versionPeer revieweden
dc.format.extent7
dc.format.mimetypeapplication/pdfen_US
dc.identifier.citationvan Amerongen, M J, Mariappan, P, Voglreiter, P, Flanagan, R, Jenniskens, S F M, Pollari, M, Kolesnik, M, Moche, M & Fütterer, J J 2021, 'Software-based planning of ultrasound and CT-guided percutaneous radiofrequency ablation in hepatic tumors', International Journal of Computer Assisted Radiology and Surgery, vol. 16, no. 6, pp. 1051-1057. https://doi.org/10.1007/s11548-021-02394-1en
dc.identifier.doi10.1007/s11548-021-02394-1en_US
dc.identifier.issn1861-6410
dc.identifier.issn1861-6429
dc.identifier.otherPURE UUID: a47463de-43ff-41ba-a840-6c412f5dda19en_US
dc.identifier.otherPURE ITEMURL: https://research.aalto.fi/en/publications/a47463de-43ff-41ba-a840-6c412f5dda19en_US
dc.identifier.otherPURE FILEURL: https://research.aalto.fi/files/63277389/Amerongen2021_Article_Software_basedPlanningOfUltras.pdf
dc.identifier.urihttps://aaltodoc.aalto.fi/handle/123456789/107920
dc.identifier.urnURN:NBN:fi:aalto-202106027173
dc.language.isoenen
dc.publisherSpringer
dc.relation.ispartofseriesInternational Journal of Computer Assisted Radiology and Surgeryen
dc.relation.ispartofseriesVolume 16, issue 6, pp. 1051-1057en
dc.rightsopenAccessen
dc.subject.keywordLiveren_US
dc.subject.keywordRFAen_US
dc.subject.keywordSimulation softwareen_US
dc.titleSoftware-based planning of ultrasound and CT-guided percutaneous radiofrequency ablation in hepatic tumorsen
dc.typeA1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäfi
dc.type.versionpublishedVersion

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Amerongen2021_Article_Software_basedPlanningOfUltras.pdf
Size:
855.48 KB
Format:
Adobe Portable Document Format