Analysis of 37 kW Converter-Fed Induction Motor Losses
Loading...
Access rights
© 2016 Institute of Electrical & Electronics Engineers (IEEE). Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work.
Post print
URL
Journal Title
Journal ISSN
Volume Title
School of Electrical Engineering |
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä
Unless otherwise stated, all rights belong to the author. You may download, display and print this publication for Your own personal use. Commercial use is prohibited.
Date
Major/Subject
Mcode
Degree programme
Language
en
Pages
9
Series
IEEE Transactions on Industrial Electronics. Issue 99
Abstract
This paper presents an energy efficiency analysis of a 37 kW standard squirrel-cage induction motor under sinusoidal and non-sinusoidal supply. The motor losses are analyzed using the conventional IEC loss segregation method and also numerically modeled using finite element simulations. The measured and simulated loss components are compared with three different modulation methods. The overall simulated losses are in good agreement with the measured ones, but there exist differences in the loss components.Description
Other note
Citation
Aarniovuori, Lassi & Rasilo, Paavo & Niemela, Markku & Pyrhonen, Juha. 2016. Analysis of 37 kW Converter-Fed Induction Motor Losses. IEEE Transactions on Industrial Electronics. Issue 99. 9. ISSN 0278-0046 (printed). DOI: 10.1109/tie.2016.2555278.