Spectral irradiance and radiation temperature scales

 |  Login

Show simple item record

dc.contributor Aalto-yliopisto fi
dc.contributor Aalto University en
dc.contributor.advisor Kärhä, Petri, Prof.
dc.contributor.author Ojanen, Maija
dc.date.accessioned 2012-08-24T08:01:00Z
dc.date.available 2012-08-24T08:01:00Z
dc.date.issued 2010
dc.identifier.isbn 978-952-60-3156-9 (electronic)
dc.identifier.isbn 978-952-60-3155-2 (printed) #8195;
dc.identifier.issn 1795-4584
dc.identifier.uri https://aaltodoc.aalto.fi/handle/123456789/4770
dc.description.abstract Spectral irradiance and radiation temperature measurements are needed in various applications, from environmental studies to different fields of industry. Scale realizations are needed to serve the calibration needs of these applications. In this thesis, I present various improvements to the scales of spectral irradiance and radiation temperature. A physical model was developed for tungsten halogen lamps utilized as spectral irradiance sources. The model consists of Planck's radiation law, emissivity of tungsten in polynomial form, and a correction function. The model can interpolate the spectral irradiance values of lamps with an agreement better than 1 % with previous calibrations by MIKES/TKK and NPL (UK) throughout the spectral region 340 nm - 850 nm. Spectral irradiance scales of MIKES/TKK and NMC (Singapore) were compared using an automated multi-wavelength filter radiometer. The wavelength range of the comparison was 290 nm - 900 nm. The agreement was compared with the results of the previous key comparison. The results indicated that the long-term reproducibility of the spectral irradiance scale of MIKES is excellent in the wavelength range above 400 nm. In the range 290 nm - 400 nm, the reproducibility is within 2.8 %, which is still within the expanded uncertainties of the comparison. The spectral irradiance scale of NIMT (Thailand) was linked to the CIPM key comparison reference value using MIKES as a link in a bilateral key comparison. I present a method for uncertainty estimation in linking key comparisons. A detector-based radiation temperature scale was developed at MIKES. Filter radiometers were first compared with a Ag fixed point cell, and then with a linear pyrometer in the temperature range of 1370 K - 1770 K. With help of the filter radiometers, the extrapolation of the pyrometer readings could be studied. The radiation temperature scales of MIKES and PTB (Germany) were compared in the range 1570 K - 2770 K. Both the International Temperature Scale of 1990 (ITS-90) and thermodynamic temperature scales were compared. The ITS-90 based scales were in agreement. The agreement of the thermodynamic temperature scales was partial: The results for two out of four filter radiometers of MIKES agreed with each other and with those of PTB, whereas the results from the two others showed deviations. Possible reasons for this deviation, such as differences in measurement geometries and possible diffuse transmittance in the interference filters, are postulated and discussed. en
dc.format.extent Verkkokirja (843 KB, 65 s.)
dc.format.mimetype application/pdf
dc.language.iso en en
dc.publisher Aalto-yliopiston teknillinen korkeakoulu en
dc.relation.ispartofseries TKK dissertations, 223 en
dc.relation.haspart [Publication 1]: Maija Ojanen, Petri Kärhä, and Erkki Ikonen. 2010. Spectral irradiance model for tungsten halogen lamps in 340–850nm wavelength range. Applied Optics, volume 49, number 5, pages 880-886. © 2010 Optical Society of America (OSA). By permission. en
dc.relation.haspart [Publication 2]: Y. J. Liu, G. Xu, M. Ojanen, and E. Ikonen. 2009. Spectral irradiance comparison using a multi-wavelength filter radiometer. Metrologia, volume 46, number 4, pages S181-S185. © 2009 Bureau International des Poids et Mesures (BIPM) and © 2009 Institute of Physics Publishing (IOPP). By permission. en
dc.relation.haspart [Publication 3]: M. Ojanen, M. Shpak, P. Kärhä, R. Leecharoen, and E. Ikonen. 2009. Uncertainty evaluation for linking a bilateral key comparison with the corresponding CIPM key comparison. Metrologia, volume 46, number 5, pages 397-403. © 2009 Bureau International des Poids et Mesures (BIPM) and © 2009 Institute of Physics Publishing (IOPP). By permission. en
dc.relation.haspart [Publication 4]: M. Ojanen, V. Ahtee, M. Noorma, T. Weckström, P. Kärhä, and E. Ikonen. 2008. Filter radiometers as a tool for quality assurance of temperature measurements with linear pyrometers. International Journal of Thermophysics, volume 29, number 3, pages 1084-1093. © 2008 Springer Science+Business Media. By permission. en
dc.relation.haspart [Publication 5]: M. Ojanen, K. Anhalt, J. Hartmann, S. Schiller, T. Weckström, P. Kärhä, M. Heinonen, and E. Ikonen. 2010. Comparison of the radiation temperature scales between MIKES and PTB. Measurement, volume 43, number 2, pages 183-189. © 2009 Elsevier Science. By permission. en
dc.subject.other Physics
dc.subject.other Electrical engineering
dc.title Spectral irradiance and radiation temperature scales en
dc.type G5 Artikkeliväitöskirja fi
dc.contributor.school Aalto-yliopiston teknillinen korkeakoulu fi
dc.contributor.department Signaalinkäsittelyn ja akustiikan laitos fi
dc.contributor.department Department of Signal Processing and Acoustics en
dc.subject.keyword filter radiometer en
dc.subject.keyword key comparison en
dc.subject.keyword radiation temperature en
dc.subject.keyword spectral irradiance en
dc.subject.keyword tungsten halogen lamp en
dc.identifier.urn URN:ISBN:978-952-60-3156-9
dc.type.dcmitype text en
dc.type.ontasot Väitöskirja (artikkeli) fi
dc.type.ontasot Doctoral dissertation (article-based) en
dc.contributor.supervisor Ikonen, Erkki, Prof.


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search archive


Advanced Search

article-iconSubmit a publication

Browse

My Account