dc.contributor |
Aalto-yliopisto |
fi |
dc.contributor |
Aalto University |
en |
dc.contributor.author |
Harnefors, Lennart |
|
dc.contributor.author |
Rahman, F. M. Mahafugur |
|
dc.contributor.author |
Hinkkanen, Marko |
|
dc.contributor.author |
Routimo, Mikko |
|
dc.date.accessioned |
2020-02-28T09:29:59Z |
|
dc.date.available |
2020-02-28T09:29:59Z |
|
dc.date.issued |
2020-02-03 |
|
dc.identifier.citation |
Harnefors , L , Rahman , F M M , Hinkkanen , M & Routimo , M 2020 , ' Reference-feedforward power-synchronization control ' , IEEE Transactions on Power Electronics , vol. 35 , no. 9 , 8978738 , pp. 8878-8881 . https://doi.org/10.1109/TPEL.2020.2970991 |
en |
dc.identifier.issn |
0885-8993 |
|
dc.identifier.issn |
1941-0107 |
|
dc.identifier.other |
PURE UUID: 532bf5a7-63e2-4320-8d6e-f272284f3077 |
|
dc.identifier.other |
PURE ITEMURL: https://research.aalto.fi/en/publications/532bf5a7-63e2-4320-8d6e-f272284f3077 |
|
dc.identifier.other |
PURE LINK: http://www.scopus.com/inward/record.url?scp=85084794404&partnerID=8YFLogxK |
|
dc.identifier.other |
PURE FILEURL: https://research.aalto.fi/files/41217320/ELEC_Harnefors_etal_Reference_Feedforward_IEEETraPowEle_acceptedauthormanuscript.pdf |
|
dc.identifier.uri |
https://aaltodoc.aalto.fi/handle/123456789/43253 |
|
dc.description.abstract |
In this letter, an enhancement of power-synchronization control is proposed, whereby pole-zero cancellation in the closed-loop system is achieved. An effect thereof is that step-response ringing and overshoot are eliminated. For strong grids, the closed-loop bandwidth increases, allowing a shorter step-response rise time. |
en |
dc.format.extent |
5 |
|
dc.format.mimetype |
application/pdf |
|
dc.language.iso |
en |
en |
dc.publisher |
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
|
dc.relation.ispartofseries |
IEEE Transactions on Power Electronics |
en |
dc.rights |
openAccess |
en |
dc.title |
Reference-feedforward power-synchronization control |
en |
dc.type |
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä |
fi |
dc.description.version |
Peer reviewed |
en |
dc.contributor.department |
ABB Corporate Research Center - Sweden |
|
dc.contributor.department |
Electric Drives |
|
dc.contributor.department |
Department of Electrical Engineering and Automation |
|
dc.contributor.department |
ABB Oy Drives |
|
dc.subject.keyword |
Grid-connected converters |
|
dc.subject.keyword |
Robusteness |
|
dc.subject.keyword |
Stability analysis |
|
dc.subject.keyword |
Voltage-source converters |
|
dc.identifier.urn |
URN:NBN:fi:aalto-202002282302 |
|
dc.identifier.doi |
10.1109/TPEL.2020.2970991 |
|
dc.type.version |
acceptedVersion |
|